GST DC-9105E Konvansiyonel Işın Tipi Dedektör
DC-9105EGST DC-9105E, EN54 (CE) ürün gamında yer alan konvansiyonel ışın tipi dedektör modelidir. Öne çıkan değerler: çalışma gerilimi DC 24V (16V~28V).
- Sertifika
- EN 54
- Sistem tipi
- Konvansiyonel
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- 24V powered.
- Wide operating voltage range, large monitoring areas.
- Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
- Built-in microprocessor enables Conventional judgment about fire alarm and fault.
- Easy alignment and commissioning via supporting of onboard laser pointer and digital signal intensity indication.
- Self-diagnostic function can monitor the internal fault.
- Drift compensation for factors changing, such as a certain of dust accumulation, positional excursion, 21 21 Structure and Operation Principle 1) Appearance of the detector is shown in Fig.1.
- It is not roofed.
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Teknik Özellikler 19 satır
| Mounting Distance | Length Type |
|---|---|
| 5~20m | 20 |
| 20~40m | 40 |
| 40~70m | 70 |
| 70~100m | 100 (factory default) |
| Çalışma Gerilimi | DC 24V (16V~28V) |
| Commission current | ≤20mA |
| Bekleme Akımı | ≤12mA |
| Alarm Akımı | ≤22mA |
| Angle of Adjusting | -6° ~ +6° |
| Maximum angular misalignment | ±0.5° |
| Hassasiyet Seviyesi | Level 1: 1.3dB Level 2: 1.8dB (factory default) Level 3: 2.3dB Level 4: 2.8dB (not EN 54-12:2015approved) |
| Çalışma Ortamı | -10°C ~ 50°C, ≤95%, non-condensing |
| Length of Optical Pathway | 5m~100m |
| Monitoring Area | Maximum monitoring area: 14 x100 =1400m² Maximum width: 14m |
| Material and Color of of Enclosure | ABS, Gray |
| IP Koruma Sınıfı | IP20 without glue-seal for indoor use only IP66 through glue-seal Treatment for outdoor use |
| Boyutlar | 206mm X 95mm X 95mm |
| Ağırlık | About 450g |
Genel bakış
GST DC-9105E kullanım alanları ve özellikleri.
GST DC-9105E, EN54 (CE) ürün gamında yer alan konvansiyonel ışın tipi dedektör modelidir. Öne çıkan değerler: çalışma gerilimi DC 24V (16V~28V).
GST DC-9105E Conventional Reflective Beam Detector
DC-9105E is a conventional reflective beam detector, powered by 24V. with excellent built-in microprocessor, the detector can carry out system adjustment, drift compensation of ambient data, and judgment of fire and fault through fixed algorithm. The detector has an integral visible laser pointer and 2 bits digital tube. It is easy to install and align with the reflector, convenient for commissioning with indications of 2 bits digital tube displaying received light intensity. The sensitivity of the detector can be set through handheld programmer in field, suitable for various applications including large storage zones, shopping malls, fitness centers, gyms, exhibition halls, hotel lobbies and areas with complex ceilings.
Özellikler
- 24V powered.
- Wide operating voltage range, large monitoring areas.
- Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
- Built-in microprocessor enables Conventional judgment about fire alarm and fault.
- Easy alignment and commissioning via supporting of onboard laser pointer and digital signal intensity indication.
- Self-diagnostic function can monitor the internal fault.
- Drift compensation for factors changing, such as a certain of dust accumulation, positional excursion, 21 21 Structure and Operation Principle 1) Appearance of the detector is shown in Fig.1.
- It is not roofed.
- The ceiling is lower than 1.5m.
- There is much dust, powder or vapor.
- It generates a lot of dust in some certain conditions even though it is clean in normal state.
- The places are very hot. Note: The air temperature in the transparent ceiling will exceed 55℃ while the sun is shining.
Nerelerde kullanılır?
Yangını duman veya ısı artışıyla en erken aşamada algılayarak yangın alarm paneline bildirir; tahliye için kritik zaman kazandırır.
Kurulum ve uyumluluk
Yangın algılama sistemleri; Binaların Yangından Korunması Hakkında Yönetmelik ve TS EN 54 standardına uygun olarak projelendirilmeli ve yetkili ekiplerce devreye alınmalıdır.
Tüm özellikler
- 24V powered.
- Wide operating voltage range, large monitoring areas.
- Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
- Built-in microprocessor enables Conventional judgment about fire alarm and fault.
- Easy alignment and commissioning via supporting of onboard laser pointer and digital signal intensity indication.
- Self-diagnostic function can monitor the internal fault.
- Drift compensation for factors changing, such as a certain of dust accumulation, positional excursion, 21 21 Structure and Operation Principle 1) Appearance of the detector is shown in Fig.1.
- It is not roofed.
- The ceiling is lower than 1.5m.
- There is much dust, powder or vapor.
- It generates a lot of dust in some certain conditions even though it is clean in normal state.
- The places are very hot. Note: The air temperature in the transparent ceiling will exceed 55℃ while the sun is shining.
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
DC-9105E hakkında kısa yanıtlar.
DC-9105E adresli mi, konvansiyonel mi?
DC-9105E EN 54 sertifikalı mı?
DC-9105E fiyatı ne kadar?
Hızlı teklif
Formu doldurun, DC-9105E için fiyat ve teslim süresini iletelim.
Yangın Dedektörü
GST CE (EN54) Ürünleri