GST102AGST GST102A, EN54 (CE) ürün gamında yer alan konvansiyonel yangın alarm paneli modelidir. Öne çıkan değerler: standart: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006.
- Bölge (zone)
- 2 bölge
- Sertifika
- EN 54
- Sistem tipi
- Konvansiyonel
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
- Each zone can be programed work as fire alarm (default) or supervisory alarm mode
- Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition.
- 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
- 1x Disable/supervisory relay ouput (N/O COM N/C)
- 1 x Fault output (N/O COM N/C)
- 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
- Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Teknik Özellikler 13 satır
| Şebeke Beslemesi | +10% 220/230VAC -15%, 50/60Hz |
|---|---|
| Standby Power | 7AH/24VDC |
| Maximum internal resistance of the batteries | 1 |
| Bölge Sayısı | 2 |
| Cihaz Kapasitesi | 32 detectors per zone |
| End of Line for zone | AEOL (a ctive end of line) or EOLR (0.5Watt/4.7k ) |
| End of Line for others | EOLR (0.5Watt/4.7k ) Sounder output, Alarm output |
| Koruma | IP30 |
| Standart | EN54-2 1997 + A1: 2006, EN 54-4 1997+A1: 2002+A2:2006 |
| Onaylar | LPCB |
| Çalışma Ortamı | 0°C ~ +40°C 95%, non condensing |
| Boyutlar | 430mm(W)x320mm(H)x98mm(D) |
| Ağırlık | 4.0kg |
Sertifikalar 2 satır
| Standartlar | EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006 |
|---|---|
| Sertifikalar | LPCB Technic al Specification Primary Supply 220/230VAC + -11 50 %% , 50/60Hz Standby Power 7AH/24VDC Maximum internal resistance of the 1 batteries Zone Quantity 2 Device Capacity 32 detectors per zone End of Line for AEOL (a ctive end of line) or EOLR zone (0.5Watt/4.7k ) End of Line for EOLR (0.5Watt/4.7k ) others Sounder output, Alarm output Protection IP30 EN54-2 1997 + A1: 2006, Standard EN 54-4 1997+A1: 2002+A2:2006 Approval LPCB Operating 0°C ~ +40°C Environment 95%, non condensing Dimen |
Genel bakış
GST GST102A kullanım alanları ve özellikleri.
GST GST102A, EN54 (CE) ürün gamında yer alan konvansiyonel yangın alarm paneli modelidir. Öne çıkan değerler: standart: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006.
GST GST102A Conventional Fire Alarm Control Panel
GST102A Conventional Fire Alarm Control Panel is designed in compliance with EN 54-2 1997 + A1: 2006 & EN 54-4 1997+A1: 2002+A2:2006 standard. It’s compatible with GST conventional detectors, manual call points and sounders. The panel is easy to install and operate. Control functions are enabled by a key switch. Programming functions are enabled by a key switch and an internal switch.
Özellikler
- 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
- Each zone can be programed work as fire alarm (default) or supervisory alarm mode
- Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition. Green color on in case superisory signal triggered. 2nd abmer indicator flashes when the zone is in fault condition(0.5:0.5).
- 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
- 1x Disable/supervisory relay ouput (N/O COM N/C)
- 1 x Fault output (N/O COM N/C)
- 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
- Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
- D esigned with standby batteries and space provision for two sealed lead-acid batteries
- Easy operation to enable/disable zones, sounder outputs and alarm output
- Alarm Test function selectable with or without sounder notification
- Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay
Sertifikalar ve Uyumluluk
- Standards: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006
- Certifications: LPCB Technic al Specification Primary Supply 220/230VAC + -11 50 %% , 50/60Hz Standby Power 7AH/24VDC Maximum internal resistance of the 1 batteries Zone Quantity 2 Device Capacity 32 detectors per zone End of Line for AEOL (a ctive end of line) or EOLR zone (0.5Watt/4.7k ) End of Line for EOLR (0.5Watt/4.7k ) others Sounder output, Alarm output Protection IP30 EN54-2 1997 + A1: 2006, Standard EN 54-4 1997+A1: 2002+A2:2006 Approval LPCB Operating 0°C ~ +40°C Environment 95%, non condensing Dimensions 430mm(W)x320mm(H)x98mm(D) Weight 4.0kg
Nerelerde kullanılır?
Binadaki dedektör, buton ve sirenleri yöneten yangın algılama sisteminin merkezidir; alarmın yerini gösterir, tahliye uyarısını başlatır ve diğer sistemlerle (asansör, havalandırma, kapılar) entegre çalışır.
Kurulum ve uyumluluk
Yangın algılama sistemleri; Binaların Yangından Korunması Hakkında Yönetmelik ve TS EN 54 standardına uygun olarak projelendirilmeli ve yetkili ekiplerce devreye alınmalıdır.
Tüm özellikler
- 2 zones.Each zone can have maximum 32 conventional detectors. The total number of detectors and call points in a zone shall not exceed 32
- Each zone can be programed work as fire alarm (default) or supervisory alarm mode
- Each zone include 2 indicators, 1st indicator is bi-color( Red and Green), factory default to indicate fire condition. Red color on in case fire signal triggered; also can be programed to indicate supervisory condition.
- 3x sounder outputs, output 1 can be setup 24V or N/O N/C, output 2 and 3 only work as 24V output
- 1x Disable/supervisory relay ouput (N/O COM N/C)
- 1 x Fault output (N/O COM N/C)
- 1x Auxilary power output: output current 450mA in standby mode and Maximum 1000mA in alarm mode when the Alarm Output been set to a normally open/close contact type
- Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
- D esigned with standby batteries and space provision for two sealed lead-acid batteries
- Easy operation to enable/disable zones, sounder outputs and alarm output
- Alarm Test function selectable with or without sounder notification
- Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
GST102A hakkında kısa yanıtlar.
GST102A adresli mi, konvansiyonel mi?
GST102A kaç bölge (zone) destekler?
GST102A EN 54 sertifikalı mı?
GST102A fiyatı ne kadar?
Hızlı teklif
Formu doldurun, GST102A için fiyat ve teslim süresini iletelim.
Yangın Alarm Paneli
GST CE (EN54) Ürünleri