Hikvision DS-3E1726HP-SI-24P2X Aksesuar
DS-3E1726HP-SI-24P2XHikvision DS-3E1726HP-SI-24P2X aksesuar: 24 × Gigabit PoE port,2 × 10G fiber optical port, Total PoE Power Budget 370 W, Support energy saving mode with user-configurable plans, Support IEEE 802.3az Energy Efficient Ethernet (EEE) standard, saving power during periods of low data activity, Support IE.
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- 24 × Gigabit PoE port,2 × 10G fiber optical port
- Total PoE Power Budget 370 W
- Support energy saving mode with user-configurable plans
- Support IEEE 802.3az Energy Efficient Ethernet (EEE) standard, saving power during periods of low data activity
- Support IEEE 802.1Q VLAN tagging
- Support STP/RSTP/ERPS loop prevention with storm control
- Support cable detection to locate failure
- Support SNMP, QoS, DHCP snooping, and ARP anti-spoofing
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Genel 13 satır
| Gövde | Metal material |
|---|---|
| Net Ağırlık | 3.12 kg (6.89 lb) |
| Brüt Ağırlık | 3.45 kg (7.61 lb) |
| Boyutlar (G × Y × D) | 440.0 mm × 44.0 mm × 220.8 mm (17.32'' × 1.73'' × 8.69'') |
| Çalışma Sıcaklığı | 0 °C to 45 °C (32 °F to 113 °F) |
| Depolama Sıcaklığı | -40 °C to 85 °C (-40 °F to 185 °F) |
| Çalışma Nemi | 5% to 95% (no condensation) |
| Bağıl Nem | 5% to 95% (no condensation) |
| Güç Kaynağı | 100~240 VAC, 50/60 Hz, Max. 6.3 A |
| Maks. Güç Tüketimi | 400 W |
| Boşta Güç Tüketimi | 10 W |
| Aşırı Gerilim Koruması | 6 kV |
| Montaj Şekli | Rack (equipped with mounting ears) |
Ağ Parametreleri 5 satır
| Portlar | 24 × Gigabit PoE port,2 × 10G fiber optical port |
|---|---|
| MAC Adres Tablosu | 16 K |
| Anahtarlama Kapasitesi | 88 Gbps |
| Paket İletim Hızı | 65.47 Mpps |
| Dahili Önbellek | 8.4 Mbits |
Yazılım Fonksiyonları 15 satır
| Uzun Menzil | Ports 1 to 24: up to 300 m.; Long range performance may vary depend on camera model or cable condition. |
|---|---|
| Port Isolation | Ports 1 to 26: port isolation mode to improve network security; Ports in an isolation group cannot communicate with each other, but they can communicate with ports outside the isolation group. |
| PoE Watchdog | Ports 1 to 24: Auto detect and restart the cameras that do not respond. |
| Link Aggregation | Link aggregation is used to aggregate multiple physical ports to form a logical port for load balancing, bandwidth expansion, and port protection.; Support static link aggregation.; Support 8 aggregation group(s). |
| QoS | QoS is used to allocate bandwidth to different services so as to provide end-to-end service quality assurance.; Support port-based priority configuration.; Support SP and WRR priority scheduling modes.; Support DSCP-based QoS policy. |
| Loop Prevention | Loop prevention is used to prevent the switching network from forming loops, which will seriously affect network communication. Disabled by default.; Support 802.1D STP.; Support 802.1w RSTP.; Support G.8032 ERPS. |
| VLAN | VLAN is used for network scale planning and network health improvement.; Support 802.1Q.; Configurable VLAN ID from 1-4094.; Support Trunk, Access port mode.; Support Max. 1024 VLAN. |
| HPP | Support one-click activation and remote management via Hik-Partner Pro. Functions supported: 1. Display the port rate.; 2. Display the port bandwidth utilization rate.; 3. Display the PoE power usage.; 4. Display topology information.; 5. Display the alarm status.; 6. Restart ports and devices.; 7. Enable port long-rage mode.; 8. Remotely upgrade the device. |
| System Maintenance | Support device management via web.; Support DHCP Client. Enabled by default for dynamic assignment of management IP addresses.; Support Super IP, which is a configurable IP address (default: 10.180.190.200) for direct access.; Support management via Hik-Central Pro.; Support remote management via Hik-Partner Pro.; Support cable detection. Abnormal open circuits and short circuits as well as network cable length can be detected.; Support 802.1ab LLDP for peer device discovery.; Support SNMP v1/v2 |
| Port Rate-Limiting | Port rate-limiting is used for port bandwidth adjustment to prevent network congestion. |
| Storm Control | Storm control is used to prevent switch ports from being blocked by broadcast or multicast storms in the LAN, which may affect network communication.; Support port rate limiting based on broadcast, multicast, and unknown unicast packets. |
| DHCP Snooping | DHCP Snooping can prevent unauthorized connections to DHCP servers from disrupting the network and affecting normal network communication, and only allow DHCP packets from trusted ports to pass through. Disabled by default. |
| ACL | Support ACL definitions based on source/destination MAC address, source/destination IP address, IP protocol type.; Support ACL application on ports.; Support IPv4 ACL and MAC ACL configurations.; Support inbound ACLs. |
| IPSG | IPSG can control the security of port access device.; Support port, MAC, IP binding.; Support 64 security entries. |
| DDM (Digital Diagnostic Monitoring) | Support real-time monitoring of key parameters in optical modules, such as operating temperature, operating voltage, operating current, and Rx and Tx optical power. |
PoE Güç Beslemesi 7 satır
| PoE Standardı | Ports 1 to 4: IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt; Ports 5 to 24: IEEE 802.3af, IEEE 802.3at |
|---|---|
| PoE Güç Pinleri | Ports 1 to 4: 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-); Ports 5 to 24: End-span: 1/2(-), 3/6(+) |
| PoE Portu | Hi-PoE: Ports 1 to 4; PoE: Ports 5 to 24 |
| Maks. Port Gücü | Ports 1 to 4: 90 W; Ports 5 to 24: 30 W |
| PoE Bütçesi | 370 W |
| PoE Power Saving | Power conservation is achieved by scheduling PoE to be enabled or disabled so that the PoE port(s) will cut off power to IPCs during idle periods. |
| Perpetual PoE | Supported; PoE remains active during system reboot, except in cases of power outage or PSE firmware upgrade. |
Onaylar 3 satır
| EMC | CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020), IC (ICES-003: Issue 7:2020), RCM (AS/NZS CISPR 32: 2015) |
|---|---|
| Güvenlik | CE-LVD (EN 62368-1: 2014+A11: 2017), CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition)) |
| Kimyasal Uyumluluk | CE-RoHS (2011/65/EU); WEEE (2012/19/EU); Reach (Regulation (EC) No.1907/2006) |
Genel bakış
Hikvision DS-3E1726HP-SI-24P2X kullanım alanları ve özellikleri.
Hikvision DS-3E1726HP-SI-24P2X, Smart Managed Series ürün ailesinden bir Aksesuar modelidir.
DS-3E1726HP-SI-24P2X
- 24 × Gigabit PoE port,2 × 10G fiber optical port
- Total PoE Power Budget 370 W
- Support energy saving mode with user-configurable plans
- Support IEEE 802.3az Energy Efficient Ethernet (EEE) standard, saving power during periods of low data activity
- Support IEEE 802.1Q VLAN tagging
- Support STP/RSTP/ERPS loop prevention with storm control
- Support cable detection to locate failure
- Support SNMP, QoS, DHCP snooping, and ARP anti-spoofing
- Support 6 kV surge protection
Tüm özellikler
- 24 × Gigabit PoE port,2 × 10G fiber optical port
- Total PoE Power Budget 370 W
- Support energy saving mode with user-configurable plans
- Support IEEE 802.3az Energy Efficient Ethernet (EEE) standard, saving power during periods of low data activity
- Support IEEE 802.1Q VLAN tagging
- Support STP/RSTP/ERPS loop prevention with storm control
- Support cable detection to locate failure
- Support SNMP, QoS, DHCP snooping, and ARP anti-spoofing
- Support 6 kV surge protection
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
DS-3E1726HP-SI-24P2X hakkında kısa yanıtlar.
DS-3E1726HP-SI-24P2X fiyatı ne kadar?
Hızlı teklif
Formu doldurun, DS-3E1726HP-SI-24P2X için fiyat ve teslim süresini iletelim.
Aksesuar
Hikvision Smart Managed Series
Hikvision DS-3E1105P-EI/M V2 4 Port PoE Switch
Hikvision DS-3E1106P-EI/M 4 Port PoE Switch
Hikvision DS-3E1309P-EI/M 8 Port PoE Switch
Hikvision DS-3E1309P-EI/M(B) 8 Port PoE Switch
Hikvision DS-3E1310HP-EI (B) 8 Port PoE Switch