Distribütör garantili ürünlerFaturalı satış · 81 ile sevkiyatAynı gün teklif
PoE Switch RG-S6100

Ruijie RG-S6120-24XMG4XS4VS-UP-H 24 Port 10G PoE++ 4×10G SFP+ 4×25G SFP28 Yönetilebilir Switch

ModelRG-S6120-24XMG4XS4VS-UP-H

Ruijie RG-S6120-24XMG4XS4VS-UP-H, 24 portlu bir PoE switch'tir. PoE portları IP kamera, access point ve IP telefon gibi cihazları tek ağ kablosu üzerinden besler; toplam PoE bütçesi 90 W. VLAN, QoS ve port izleme gibi yönetim özellikleri sunar.

Port hızı
10G uplink
PoE
PoE
Port sayısı
24 port
Fiyat ve stok bilgisi alınAynı gün dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
81 ile sevkiyat
Teknik destek
  • 24 x 100/1000/2.5G/5G/10GBASE-T ports for access, 4 x 1GE/10GE SFP+ ports and 4 x 10GE/25GE SFP28 ports for uplink, meeting high bandwidth demands of large campuses
  • Multi-level hardware protection, ensuring continuous device operation and stable network connectivity
  • VSU, delivering flexible networking capabilities and high performance
  • Multiple network security policies and real-time monitoring, ensuring consistently high network performance
  • Intelligent fan speed adjustment and auto port sleeping, reducing power consumption and noises
  • Various network management methods, achieving simplified network maintenance

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri 6 satır
Sabit Servis Portları24 x 100/1000/2.5G/5G/10GBASE-T ports, supporting PoE/PoE+/PoE++; 4 x 1GE/10GE SFP+ ports; 4 x 10GE/25GE SFP28 ports
Modül Yuvası2 x power module slots; 3 x fan module slots
Güç ModülüRG-PA600I-P-F; RG-PA1000I-P-F
Fan ModülüM2SFAN I-F (pre-installed 3)
Sabit Yönetim Portu1 x RJ45 console port; 1 x RJ45 MGMT port
USB1 x USB 2.0 port
Sistem Özellikleri 8 satır
Sistem Paket İletim Hızı678 Mpps
Sistem Anahtarlama Kapasitesi912 Gbps
İşlemci (CPU)Single-core CPU, with the clock speed of 1.2 GHz
Gerçek Zamanlı Saat (RTC)Destekleniyor
BootROM16 MB (storing boot software for 1+1 boot redundancy)
Flash Bellek1 GB (storing boot software for 1+1 boot redundancy)
Bellek1 GB DDR4 (32-bit width, 4-bit ECC)
Switch Tampon Belleği4 MB
*2 means the system's switching capacity. 7 satır
Güç Kaynağı2 x pluggable power modules
Güç GirişiRG-PA600I-P-F (AC input):; Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Maximum input current: 8 A; RG-PA1000I-P-F (AC input 1):; Rated input voltage: 100 V AC to 130 V AC, 50/60 Hz; Maximum input voltage: 90 V AC to 143 V AC, 47 Hz to 63 Hz; Maximum input current: 12 A; RG-PA1000I-P-F (AC input 2):; Rated input voltage: 200 V AC to 240 V AC, 50/60 Hz; Maximum input voltage: 180 V AC to 264 V AC, 47 Hz to 63 Hz
Maks. Çıkış GücüRG-PA600I-P-F: 600 W; RG-PA1000I-P-F:; 100 V AC to 130 V AC: 930 W; 200 V AC to 240 V AC: 1000 W
PoE PortuPorts 1 to 24 support PoE/PoE+/PoE++ (IEEE802.3af/at/bt) power supply
PoE power cable pairsFour pairs (1-2, 3-6, 4-5, and 7-8 pairs)
PoE Çıkış GücüEach PoE port provides up to 90 W of power; The maximum power depends on the configured power supply; 1 x RG-PA600I-P-F:450 W; 1 x RG-PA1000I-P-F: 760 W (100 V AC to 130 V AC); 1 x RG-PA1000I-P-F: 850 W (200 V AC to 240 V AC); 2 x RG-PA600I-P-F:930 W; 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1200 W (100 V AC to 130 V AC); 1 x RG-PA600I-P-F + 1 x RG-PA1000I-P-F:1290 W (200 V AC to 240 V AC); 2 x RG-PA1000I-P-F: 1470 W (100 V AC to 130 V AC); 2 x RG-PA1000I-P-F: 1650 W (200 V AC to 240 V AC)
Maks. Güç Tüketimi150 W (without PoE load); 1,800 W (full PoE load)
Boyutlar ve Ağırlık 5 satır
Cihaz Boyutları (G x D x Y)442.0 mm x 420.0 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.)
Kutu Boyutları (G x D x Y)563 mm x 563 mm x 210 mm (22.17 in. x 22.17 in. x 8.27 in.)
Kabin Yüksekliği1 RU
Cihaz Ağırlığı5.86 kg (12.92 lbs, with 3 fan modules)
Kutulu Ağırlık8.12 kg (17.90 lbs, with 3 fan modules)
Ortam ve Güvenilirlik 17 satır
SıcaklıkOperating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: -40°C to +70°C (-40°F to +158°F); Note: At an altitude between 3,000 m (9,842.52 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F).
NemOperating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing)
RakımOperating altitude: –500 m to +5,000 m (–1640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1640.42 ft. to +16,404.20 ft.)
MTBF194,296 hours (about 22 years)
Fan3 x pluggable fan modules
Isı DağılımıFan cooling, left-to-rear and front-to-rear airflow
Gürültü Seviyesi27°C (80.6°F): 60 dB; Maximum value: < 78 dB
Güç Modülü Yedekliliği1+1 redundancy
Fan Yedekliliği2+1 redundancy
Güç Modülü Sıcak TakasDestekleniyor
USB hot swappingDestekleniyor
Cable hot swappingDestekleniyor
Güç Kaynağı İzlemeMonitoring of the power supply model and status; Power supply failure alarming
Fan İzlemeAutomatic speed adjustment; Fan failure alarming
Sıcaklık İzlemeDestekleniyor
ESD KorumasıESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV
Aşırı Gerilim KorumasıMGMT port: 4 kV; Service port: 8 kV; Power port: common mode 6 kV, differential mode 6 kV
Sertifikalar ve Uyumluluk 3 satır
Güvenlik StandardıIEC 62368-1
EMC StandardıEN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
RoHSEuropean RoHS Directive 2011/65/EU & Amendment(EU) 2015/863
Performans ve Kapasite 14 satır
Maks. VSU Üye Sayısı4
VSU bandwidthS6110-24MG4VS-UP: 100 Gbps; S6110-48MG4VS2QXS-UP: 180 Gbps; S6120-24XMG4XS4VS-UP-H: 140 Gbps; S6120-48XMG4VS2QXS-UP-H: 200 Gbps
Maximum number of SVIs1,000
Maks. MAC Adres Kaydı32,768
Maks. ARP Kaydı160,000
Maximum number of ND entries4,000
Maks. IPv4 Unicast Rota16,000 (shared with IPv6 routes)
Maks. IPv6 Unicast Rota8,000 (shared with IPv4 routes)
Maximum number of IPv4 multicast routes4,000
Maximum number of IPv6 multicast routes2,000
Maximum number of IGMP groups4,000
Maximum number of MLD groups2,000
Maximum number of VRF instances100
Maximum number of ACEsIn: 2,500 Out: 1,000
Fonksiyonlar 9 satır
Ethernet AnahtarlamaJumbo frame (maximum length: 9,216 bytes); IEEE 802.1Q (supporting 4K VLANs); Maximum number of VLANs that can be created: 4,094; Voice VLAN; Super-VLAN and private VLAN; MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment; GVRP; Basic QinQ and selective QinQ; STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s); ERPS (G.8032); LACP (IEEE 802.3ad); LLDP/LLDP-MED
IP ServisleriStatic and dynamic ARP; DHCP server, DHCP client, DHCP relay, and DHCP snooping; DNS; DHCPv6 server, DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping; Neighbor Discovery (ND) and ND snooping
IP YönlendirmeStatic routing; RIP and RIPng; OSPFv2 and OSPFv3; GR; IS-ISv4 and IS-ISv6; BGP4 and BGP4+; Equal and Weighted Cost Multi-Path (ECMP); Packet-based and flow-based load balancing; Stateless Auto Configuration; IPv4/IPv6 VRF; IPv4/IPv6 PBR
MulticastIGMPv1/v2/v3 and IGMP proxy; IGMPv1/v2/v3 snooping; IGMP filtering and IGMP fast leave; PIM-DM, PIM-SM, and PIM-SSM; PIM-SSM for IPv4 and IPv6; MSDP to achieve inter-domain multicast; MLDv1/v2; MLD snooping; PIM-SMv6; Multicast source IP address check; Multicast source port check; Multicast querier
ACL ve QoSStandard IP ACLs (hardware ACLs based on IP addresses); Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers); Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type); Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range); Time-based ACLs; ACL80 and IPv6 ACL; Applying ACLs globally (hardware A
GüvenlikMulti-AAA; RADIUS and TACAS+; Filtering of invalid MAC addresses; Broadcast storm suppression; Hierarchical management of administrators and password protection; BPDU guard; RADIUS authentication and authorization; Port- and MAC address-based 802.1x authentication; IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication; Web authentication; Hypertext Transfer Protocol Secure (HTTPS); SSHv1 and SSHv2; Global IP-MAC bindin
GüvenilirlikREUP; ERPS (G.8032); Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control; Data Link Detection Protocol (DLDP); IPv4 VRRP v2/v3 and IPv6 VRRP; BFD; GR for RIP, OSPF, and BGP; Power modules in 1+1 redundancy mode; Hot swapping of power modules and fan modules (not supported by the RG-S6110-24MG4VS-UP)
Cihaz SanallaştırmaVSU
Ağ Yönetimi ve BakımSPAN, RSPAN, and ERSPAN; sFlow; NTP and SNTP; FTP and TFTP; SNMP v1/v2/c3; RMON (1, 2, 3, 9); Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups; RMON used to implement Ethernet statistics, historical statistics, and alarm functions; NETCONF; Flow-based mirroring, and N:1 and 1:N port mirroring; CWMP; gRPC; OpenFlow Special 1.3; Flow table analysis defined by all protocols; Transmission of specified

Genel bakış

Ruijie RG-S6120-24XMG4XS4VS-UP-H kullanım alanları ve özellikleri.

100/1000/2.5G/5G/10GBASE-T ports, PoE/PoE+/PoE++, 4 x 10GE SFP+ ports and 2 x 25GE SFP28 ports, offering flexible networking options to build high-performance campus networks

RG-S6120-24XMG4XS4VS-UP-H 10G Multi-GE Access Switches

24 x 100/1000/2.5G/5G/10GBASE-T ports and 4 x 10GE and 4 x 25GE uplink ports are provided to realize flexible networking. High-power PoE++ is provided and a maximum of 90 W PoE power supply meets different terminal needs.

Hardware Redundancy, Guaranteed Service Continuity and Network Connectivity

Hardware-Level Boot Redundancy

Optical Port Fault Isolation

Hot-Swappable Power Modules + Intelligent Fan Modules

Two Flash chips are used to store the system Boot program for hardware-level Boot redundancy, avoiding device failure caused by a failed Flash chip.

The innovative isolated chip design ensures that short-circuit current cannot reach the power supply chip directly. Failure of one optical module will not affect the normal operation of other optical ports, thus effectively ensuring service stability.

Power modules can be replaced without affecting device operation. Intelligent fan speed regulation is supported for efficient cooling, providing dual protection for the network.

VSU Virtualization, Flexible Networking and High Performance

Millisecond Failover

High Scalability

Simplified Networking

Connected by an aggregate link, the VSU virtual system and peripherals switch links in milliseconds to ensure service continuity in case of a failure.

VSU virtualization technology is supported to increase bandwidth through link aggregation, which greatly improves forwarding capabilities of the switch.

Multiple physical switches can be virtualized into one logical unit to simplify network configuration and architecture, eliminating loops, and improving reliability.

Network Security Policies and Real-Time Monitoring, Delivering Enhanced Network Robustness

CPP

NFPP

CPP protects the CPU from data attacks to ensure CPU stability under high usage, achieving significant improvement in the device's security performance.

NFPP protects CPU from high load damage to guarantee device management and operation, thus improving network security and stability.

Intelligent Speed Regulation and Auto Sleeping, Reducing Energy Consumption and Noise

Intelligent fan speed regulation based on monitored component temperatures, saving energy Auto service port sleeping, reducing device power consumption.

Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations

RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.

Nerelerde kullanılır?

IP kamera, access point ve IP telefon projelerinde cihazlara tek kablodan enerji ve veri taşır; NVR ile kameralar arasında dağıtım katmanı oluşturur.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Sık sorulanlar

RG-S6120-24XMG4XS4VS-UP-H hakkında kısa yanıtlar.

RG-S6120-24XMG4XS4VS-UP-H IP kamera beslemek için uygun mu?
Evet. PoE portları IP kameraları tek kablo üzerinden besler; toplam PoE bütçesi 90 W olduğundan kamera tüketimlerinin toplamı bu değerin altında kalmalıdır.
RG-S6120-24XMG4XS4VS-UP-H kaç portlu?
RG-S6120-24XMG4XS4VS-UP-H 24 porta sahiptir.
RG-S6120-24XMG4XS4VS-UP-H fiyatı ne kadar?
RG-S6120-24XMG4XS4VS-UP-H için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-S6120-24XMG4XS4VS-UP-H için fiyat ve teslim süresini iletelim.

Benzer ürünler

PoE Switch

Tümü
Aynı seri

Ruijie RG-S6100