Ruijie RG-CS61-48GT4MS-P 48 Port Gigabit PoE+ 4×2.5G SFP L3 Yönetilebilir Switch
RG-CS61-48GT4MS-PRuijie RG-CS61-48GT4MS-P, 48 portlu gigabit bir PoE switch'tir. PoE portları IP kamera, access point ve IP telefon gibi cihazları tek ağ kablosu üzerinden besler; toplam PoE bütçesi 370 W. VLAN, QoS ve port izleme gibi yönetim özellikleri sunar.
- Port hızı
- Gigabit
- PoE
- PoE
- Port sayısı
- 48 port
- 2.5G uplinks
- 10 kV port surge protection
- Supports operating temperatures up to 50°C
- Dual flash, dual boot, and dual bin
- Circuit isolation protection based on optical ports
- Supports up to 8 devices in a VSU
- Layer 3 service features
Genel bakış
Ruijie RG-CS61-48GT4MS-P özellikleri ve kullanım alanları.
Offices, hotels, warehouses, hospitals, and schools.
RG-CS61-48GT4MS-P Layer 3 Access Switches with 2.5G Uplinks
Access Switches with 2.5G Uplinks
Equipped with 2.5G uplinks, access switches provide higher bandwidth than traditional 1G uplinks while keeping cost under control.
8-unit stacking for flexible expansion helps maintain continuous service during device failures.
Dual-boot & Dual-bin
Dual-boot for reliable device startup and reboot, and dual-bin for redundant system partitions help maintain stable service operation.
Area-based Port Power Supply
When an optical transceiver experiences a short-circuit fault, Cybrey switches support optical port isolation to help prevent broader system impact.
Layer 3 Capabilities
Access switches with Layer 3 capabilities, including OSPF and 6,000 route entries, help contain the impact of network failures and enable faster recovery than traditional Layer 2 access switches.
10 kV Surge Protection & 50°C Operation
Compared with typical switches that support 6–8 kV surge protection and operation up to 45°C, Cybrey switches deliver 10 kV surge protection and stable performance at temperatures up to 50°C, making them suitable for harsh environments.
In the Box
M4 x 8 mm screws
Power cord retention clip
* Accessory pictures are for reference only. Specifications of accessories vary by sales region and country. Please refer to the actual item received.
Cybrey Cloud, Make Your Business Easy
MAC Address Management
Nerelerde kullanılır?
IP kamera, access point ve IP telefon projelerinde cihazlara tek kablodan enerji ve veri taşır; NVR ile kameralar arasında dağıtım katmanı oluşturur.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Sabit Servis Portları | 48 x 10/100/1000BASE-T ports, supporting PoE/PoE+; 4 x 1GE/2.5GE SFP ports |
|---|---|
| Konsol Portu | 1 |
| USB | 1 |
| Anahtarlama Kapasitesi | 116 Gbps (Gbit/s) |
| İletim Hızı | 86.3 Mpps |
| Packet buffer size | 12 Mbit |
| İşlemci (CPU) | Dual-core ARM A55 CPU frequency up to 1.0 GHz |
| SDRAM | 2 GB |
| Flash Bellek | 512 MB |
| BootROM | 16 MB |
| Gerçek Zamanlı Saat (RTC) | Evet |
| Cihaz Boyutları (G x D x Y) | 440 mm x 262.8 mm x 43.6 mm (17.32 in. x 10.35 in. x 1.72 in.) |
| Kabin Yüksekliği | 1 RU |
| Packaging dimensions (W x D x H) | 560 mm x 377 mm x 150 mm (22.05 in. x 14.84 in. x 5.91 in.) |
| Cihaz Ağırlığı | 4.3kg (9.48 lbs) |
| Packaging weight | 5.57 kg (12.28 lbs) |
| Besleme Modu | 1 x fixed power supply |
| Maks. Güç Tüketimi | Full-load:; 110 V: 456.65 W; 220 V: 446.79 W; No-load:; 110 V: 56.064 W; 220 V: 55.438 W |
| Güç Girişi | AC input; Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz; Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; Maximum input current: 6 A |
| PoE | Evet |
| PoE-out Port Sayısı | All RJ45 ports support PoE/PoE+ (IEEE802.3af/at) power supply |
| PoE Bütçesi | 370 W |
| Port Başına PoE Bütçesi | 30 W |
| PoE power cable pairs | Mode A (1-2, 3-6 pairs) |
| Çalışma Sıcaklığı | 0°C to 50°C (32°F to 122°F) |
| Depolama Sıcaklığı | –40°C to +70°C (–40°F to +158°F) |
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
| Depolama Nemi | 5% RH to 95% RH (non-condensing) |
| Çalışma Rakımı | 0 m to 5000 m (0 ft. to 16,404.20 ft.) |
| Soğutma | Air cooling, left-to-rear airflow |
| Fan | 2 x fixed fans |
| Gürültü | 27°C (80.6°F): 40 dB |
| Fan speed adjustment | Intelligent speed adjustment |
| Hot swapping of cables | Evet |
| USB hot swapping | Evet |
| Aşırı Gerilim Koruması | Service port: ±10 kV for common mode; Power connector: ±6 kV for common mode and ±6 kV for differential mode |
| ESD prevention | Contact discharge: 6 kV; Air discharge: 8 kV |
| Temperature monitoring and protection | Temperature monitoring, temperature alarm, and over-temperature protection |
| Fan İzleme | Fault alarm |
| MTBF | > 400,000 hours |
| Energy efficiency | Evet |
| Güvenlik Standartları | IEC 62368-1 EN 62368-1 |
| EMC Standartları | EN 300386, EN 55032 Class A, EN 55035,; EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN IEC 61000-4-3,; EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN IEC 61000-4-11 |
| Garanti | 5 years |
| VLAN | IEEE 802.1Q; Port-based VLAN; MAC-based VLAN; Voice VLAN; IP/Subnet-based VLAN; Protocol-based VLAN; Private VLAN; Super VLAN; GVRP |
| Spanning tree | IEEE802.1d STP; IEEE802.1w RSTP; Standard 802.1s MSTP |
| LLDP | LLDP; LLDP-MED |
| Basic QinQ | Basic QinQ; Transparent transmission of double-tagged packets |
| ARP | ARP; anyIP |
| ND | Neighbor discovery |
| VRF | IPv4 and IPv6 VRF |
| Static routing | IPv4 static routing; IPv6 static routing |
| OSPF | OSPFv2 basics; OSPFv3 basics |
| RIP | RIP; RIPv2 |
| IGMP snooping | IGMP snooping v1/v2; IGMP snooping v3 |
| IGMP | IGMPv1/v2/v3; IGMP proxy |
| MLD snooping | MLD snooping; MLD snooping v2 |
| MLD | MLDv1/v2 |
| PIM-SMv4 | PIM-SMv4; PIM-SSMv4 |
| ACL | IP standard ACL; IP extended ACL; MAC extended ACL; IPv6 ACL; Expert ACL; Time-based ACL; ACL-based redirection; ACL80 |
| QoS | Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences; SP; WRR; SP+WRR; DRR; SP+DRR; WFQ; SP+WFQ; Congestion avoidance: tail drop; Traffic shaping (ingress/egress) |
| 802.1X | Port-based authentication; MAC-based authentication |
| VSU Sanallaştırma | Device virtualization |
| VRRP | IPv4 VRRPv2; IPv4 VRRPv3; IPv6 VRRP |
| VRRP+ | IPv4 VRRP+; IPv6 VRRP+ |
| BFD | BFD detection |
| Aggregate interface | LACP basics |
| Mirroring | SPAN; RSPAN |
| SNMP | SNMPv1/v2c/v3; RMON (1, 2, 3, 9) |
| SSH | SSHv2; SSHv1 |
| PoE | Uninterrupted power supply upon warm start; PoE port priority |
| DHCP | DHCPv4 client; DHCPv4 server; DHCPv4 relay; DHCPv4 snooping; DHCPv6 client; DHCPv6 relay; DHCPv6 snooping |
| USB | USB 2.0 |
| Maximum number of created VLANs | 4094 |
| Jumbo frame length / Port MTU | 9216 |
| Layer 2 traffic convergence time | ≤ 200 ms |
| Maks. ARP Kaydı | 4000 |
| IPv4 routing table size | 6000 |
| IPv6 routing table size | 2000 |
| Maximum number of IPv4 multicast routing table entries | 1000; Number of multicast groups x Number of outbound interfaces ≤ 1000 |
| Maximum number of IPv6 multicast routing table entries | 900 |
| Maximum number of inbound ACE entries | 1750 |
| Maximum number of outbound ACE entries | 800 (The capacity can reach 800 when only Layer 2 match fields, excluding inner tags, are used. If other match fields are added, the capacity may decrease to 350.) |
| Maximum number of QoS hardware queues | 8 (shared by unicast and multicast traffic) |
| Maks. VSU Üye Sayısı | 8 |
| Main unit | 1 |
| Power cord | 1 |
| Rack-mount bracket | 2 |
| Screw | 6 x M4 x 8 mm screws |
| Rubber pad | 4 |
| Grounding wire | 1 |
| Power cord retention clip | 1 |
| User Manual | 1 |
| Warranty Card | 1 |
| PBR | IPv4 PBR; IPv6 PBR |
|---|
| PIM-SMv6 | PIM-SMv6; PIM-SSMv6 |
|---|
| Web-based authentication | HTTP-based authentication; HTTPS-based authentication |
|---|
| Global IP-MAC binding | Configuring global IP-MAC binding entries |
|---|
| CPP | Hardware CPP |
|---|
| gRPC | gRPC framework |
|---|
| DNS | DNS client; DNSv6 client |
|---|---|
| NTP | NTP client; NTP server |
| SNTP | SNTP client; SNTP |
| FTP | FTP client; FTP server |
| TFTP | TFTP client; TFTP server |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-CS61-48GT4MS-P hakkında kısa yanıtlar.
RG-CS61-48GT4MS-P IP kamera beslemek için uygun mu?
RG-CS61-48GT4MS-P kaç portlu?
RG-CS61-48GT4MS-P fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-CS61-48GT4MS-P için fiyat ve teslim süresini iletelim.
PoE Switch kategorisinden
Ruijie XS-S1920-24T2GT2SFP-P-E 4 Port Yönetilebilir PoE Switch
Ruijie RG-CS61 serisi
Ruijie RG-CS61-10GT2MS-P 10 Port Gigabit PoE+ 2×2.5G SFP L3 Yönetilebilir Switch
Ruijie RG-CS61-24GT4MS 24 Port Gigabit 4×2.5G SFP L3 Yönetilebilir Switch