Ruijie RG-N18010-XH 8 Slot Modüler Veri Merkezi Switch
RG-N18010-XHRuijie RG-N18010-XH bir yönetilebilir switch'tir. Öne çıkan özellikleri: 100ge and 400ge line cards, and up to 288 x 400ge and 1152 x 100ge line-rate ports, communication at the maximum distance of 120 km and easy dci, hardware-level redundancy, ensuring nonstop services and data center network stability, macsec data encryption and transmission, effectively protecting service data security.
- PoE
- PoE yok
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- 100GE and 400GE line cards, and up to 288 x 400GE and 1152 x 100GE line-rate ports
- Communication at the maximum distance of 120 km and easy DCI
- Hardware-level redundancy, ensuring nonstop services and data center network stability
- MACsec data encryption and transmission, effectively protecting service data security
- Innovative technology design and efficient heat dissipation, with more than 50,000 kWh saved per device each year
- Telemetry-based network monitoring and automated O&M, making management simple and efficient...
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Donanım Özellikleri 12 satır
| Boyutlar (G x D x Y) | 442 mm x 896 mm x 708 mm (17.40 in. X 35.28 in. X 27.87 in.), without the cable management bracket;; 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. X 27.87 in.), with the cable management bracket. |
|---|---|
| Kabin Yüksekliği | 16 RU |
| Cihaz Ağırlığı | 96.4 kg (212.53 lbs.) (Chassis that supports the M18000XH-CM supervisor module); 99 kg (218.26 lbs.) (Chassis that supports the M18000XH-CM II supervisor module) |
| Anahtarlama Kapasitesi | 645 Tbps/1,935 Tbps |
| Paket İletim Hızı | 345,600 Mpps |
| Modül Yuvası | 2 x supervisor module slots; 8 x line card slots; 8 x switch fabric module slots; 10 x power module slots; 3 x fan module slots |
| Güç Tüketimi | Maximum power consumption (with the M18010XH-FAN fan module): 187,600 W; Maximum power consumption (with the M18010XH-FAN III fan module): 9000 W |
| Güç Girişi | RG-PAH3000I-F (AC input):; Rated input voltage: 100 V to 130 VAC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 290 V AC, 45 Hz to 65 Hz; Rated input current: 16 A; Power port type: C20; RG-PAH3000I-F (HVDC input):; Rated input voltage: 240 V DC to 380 V DC; Maximum input voltage: 188 V DC to 400 V DC; Rated input current: 14 A; Note: When the switch is equipped with the high-voltage DC power supply, a PDU that supports high-voltage DC power supply must be used. To ensure |
| Sıcaklık | Operating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Nem | Operating humidity: 10% RH to 90% RH (non-condensing) |
| Rakım | Operating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side air intake) |
Yazılım Özellikleri 14 satır
| Traffic analysis | sFlow; IPFIX |
|---|---|
| Katman 2 Özellikleri | Jumbo frame; IEEE 802.3ad (static link aggregation, LACP, cross-module link aggregation, and M-LAG); IEEE 802.1Q; STP, RSTP, and MSTP; GVRP; QinQ; LLDP; Static MAC addresses, address filtering, and limit on the number of MAC addresses |
| IPv4 features | Static routing, BGP4, OSPF, IS-IS, and RIP; VRRP; ECMP; Policy-based routing; IP fragmentation and reassembly; Manual tunnel and GRE tunnel |
| IPv6 features | Static routing, BGP4+, OSPFv3, IS-ISv6, and RIPng; VRRPv3; ECMP; Policy-based routing; Path MTU discovery; IP fragmentation and reassembly; Manual tunnel and GRE tunnel; Pingv6, Traceroutev6, Telnetv6, FTPv6, TFTPv6, DNSv6, and ICMPv6 |
| Multicast | IGMP v1/v2/v3; IGMP Snooping v1/v2; IGMP proxy; PIM-DM, PIM-SM, PIM-SSM, and PIM-SM v6; MLDv1, MLDv2; Static multi cast route; Fast leave |
| MPLS | MPLS L3VPN; MPLS LDP; SR MPLS (Segment Routing); SR-TE |
| ACL | Standard, extended (Layer 2 to layer 4), and expert ACL; Global ACL; Ingress and egress ACL; IPv6 ACL |
| QoS | IEEE 802.1p, ToS, and DSCP priority mapping; Priority marking and remarking; SP(PQ), DRR, SP(PQ)+DRR, WFQ, SP(PQ)+WFQ, WRR, SP(PQ)+WRR and other queue scheduling mechanisms; Congestion avoidance mechanisms such as RED and WRED; ACL; Egress/ingress port-based rate limit and CAR; #MPLS QoS |
| Data center features | #SRv6; VXLAN bridge; VXLAN gateway; BGP-EVPN VXLAN; VXLAN mapping; VXLAN over IPv4; VXLAN over IPv6; M-LAG; RDMA |
| SDN | OpenFlow 1.3 |
| Güvenilirlik | Independent switch fabric modules and independent supervisor modules to implement thorough separation of the forwarding plane from the control plane; 1+1 redundancy for supervisor modules; N+M redundancy for switch fabric modules; N+M redundancy for power modules and fan modules; Midplane-free design to avoid single point of failures; Hot swapping of components; Hot patching for online patch upgrade; BPDU Guard/Loop Guard/Root guard; NSR; DLDP; FRR; GR for OSPF/IS-IS/BGP; BFD for VRRP/OSPF/BGP4/ |
| Sanallaştırma | Virtual switching unit (VSU) |
| Güvenlik | #MACSec; Network foundation protection protocol (NFPP) and CPU Protection Policy (CPP); DDoS attack defense, ARP attack defense, and ICMP attack defense; DAI, port security, IP source guard, and port protection; uRPF; RADIUS and TACACS authentication, password security, hierarchical user management, and password protection; Source IP address restriction; Configuring the device not to send unknown multicast packets to the CPU; Suppression of unknown unicast, broadcast, and multicast packets; SSHv |
| Yönetim | Console/AUX Modem/Telnet/SSHv2 CLI configuration; FTP, TFTP, Xmodem, and SFTP; SNMP v1/v2c/v3; Netconf; RMON; NTP clock; Fault alarm and auto-recovery; System operation log; Traffic analysis; Zero-Touch provisioning (ZTP); Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability; Telemetry; Buffer status monitoring and traffic microburst identification; Supported VXLAN OAM: VXLAN ping VXLAN tracert; Port mirroring, traffic mir |
Temel Özellikler 3 satır
| Dimensions (W × D × H) | 442 mm x 896 mm x 708 mm (17.40 in. X 35.28 in. X 27.87 in.), without the cable management bracket; 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. X 27.87 in.), with the cable management bracket. |
|---|---|
| Çalışma Sıcaklığı | 0ºC to 40ºC (32ºF to 104ºF) |
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
Genel bakış
Ruijie RG-N18010-XH kullanım alanları ve özellikleri.
Adaptation to 400GE ZR/ZR+ optical modules, up to 288 x 400GE and 1152 x 100GE line-rate ports, and smooth evolution to 800GE
Data Center 400GE Modular Core Switch RG-N18010-XH
The RG-N18010-XH provides 10 module slots, including eight service slots, which can be used with 100GE and 400GE line cards. It supports 800GE line cards in the future, easily coping with future bandwidth expansion needs. With various port types, the RG-N18010-XH supports up to 288 x 400GE and 1152 x 100GE line-rate ports, and allows smooth evolution to 800GE, satisfying requirements in diversified scenarios of data center networks.
Innovative Architecture Design, Achieving Highly Efficient Data Transmission
Zero Midplane
Clos Architecture
Service line cards are directly connected to SFUs, without the use of the midplane. Data can directly reach the SFU, with a short distance. This significantly reduces the transmission loss and achieves efficient data transmission.
The Clos multi-level multi-platform switching architecture separates data forwarding from control, realizing high stability. This architecture delivers 1:1 non-convergence, link load balancing based on dynamic routes, and non-blocking data forwarding.
Communication at the Maximum Distance of 120 KM and Easy DCI
400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services
Hardware-level Redundancy, Ensuring Nonstop Services and Data Center Network Stability
SFUs in N+1 Redundancy Mode
SFUs use N+1 redundancy and work in load balancing mode, ensuring nonstop services.
Power Modules in M+N Redundancy Mode
Ten hot-swappable power modules are available. When a fault occurs, services are switched within seconds. Services are not interrupted when a power module is replaced. The switch provides different protection measures for links.
Fan Trays in 2+1 Redundancy Mode
Three hot-swappable fan trays are available. The speed of fan modules can be intelligently adjusted, ensuring highly efficient heat dissipation.
Supervisor Engines in 1+1 Redundancy Mode
The 1+1 hot standby design ensure continuous operation of the switch.
Innovative Technology Design and Highly Efficient Heat Dissipation
MACsec Data Encryption and Transmission, Effectively Protecting Service Data Security
MACsec provides hardware-level data encryption. With MACsec and 802.1X configured, the switch can strictly identify and verify transmitted data. With MACsec, the switch achieves interface-based secure line-rate transmission, effectively preventing data from being intercepted and obtained maliciously and ensuring service data security.
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-N18010-XH hakkında kısa yanıtlar.
RG-N18010-XH fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-N18010-XH için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6930-2C 2 Slot Modüler Veri Merkezi Switch
Ruijie RG-S6980-64QC 64 Port 400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6980-128DC 128 Port 200G QSFP56 Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch





