Distribütör garantili ürünlerFaturalı satış · 81 ile sevkiyatAynı gün teklif
Yönetilebilir Switch RG-N18000-XH

Ruijie RG-N18010-XH 8 Slot Modüler Veri Merkezi Switch

ModelRG-N18010-XH

Ruijie RG-N18010-XH bir yönetilebilir switch'tir. Öne çıkan özellikleri: 100ge and 400ge line cards, and up to 288 x 400ge and 1152 x 100ge line-rate ports, communication at the maximum distance of 120 km and easy dci, hardware-level redundancy, ensuring nonstop services and data center network stability, macsec data encryption and transmission, effectively protecting service data security.

PoE
PoE yok
Fiyat ve stok bilgisi alınAynı gün dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
81 ile sevkiyat
Teknik destek
  • 100GE and 400GE line cards, and up to 288 x 400GE and 1152 x 100GE line-rate ports
  • Communication at the maximum distance of 120 km and easy DCI
  • Hardware-level redundancy, ensuring nonstop services and data center network stability
  • MACsec data encryption and transmission, effectively protecting service data security
  • Innovative technology design and efficient heat dissipation, with more than 50,000 kWh saved per device each year
  • Telemetry-based network monitoring and automated O&M, making management simple and efficient...

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri 12 satır
Boyutlar (G x D x Y)442 mm x 896 mm x 708 mm (17.40 in. X 35.28 in. X 27.87 in.), without the cable management bracket;; 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. X 27.87 in.), with the cable management bracket.
Kabin Yüksekliği16 RU
Cihaz Ağırlığı96.4 kg (212.53 lbs.) (Chassis that supports the M18000XH-CM supervisor module); 99 kg (218.26 lbs.) (Chassis that supports the M18000XH-CM II supervisor module)
Anahtarlama Kapasitesi645 Tbps/1,935 Tbps
Paket İletim Hızı345,600 Mpps
Modül Yuvası2 x supervisor module slots; 8 x line card slots; 8 x switch fabric module slots; 10 x power module slots; 3 x fan module slots
Güç TüketimiMaximum power consumption (with the M18010XH-FAN fan module): 187,600 W; Maximum power consumption (with the M18010XH-FAN III fan module): 9000 W
Güç GirişiRG-PAH3000I-F (AC input):; Rated input voltage: 100 V to 130 VAC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 290 V AC, 45 Hz to 65 Hz; Rated input current: 16 A; Power port type: C20; RG-PAH3000I-F (HVDC input):; Rated input voltage: 240 V DC to 380 V DC; Maximum input voltage: 188 V DC to 400 V DC; Rated input current: 14 A; Note: When the switch is equipped with the high-voltage DC power supply, a PDU that supports high-voltage DC power supply must be used. To ensure
SıcaklıkOperating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.
NemOperating humidity: 10% RH to 90% RH (non-condensing)
RakımOperating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.)
SoğutmaAir cooling, front-to-rear airflow (port-side air intake)
Yazılım Özellikleri 14 satır
Traffic analysissFlow; IPFIX
Katman 2 ÖzellikleriJumbo frame; IEEE 802.3ad (static link aggregation, LACP, cross-module link aggregation, and M-LAG); IEEE 802.1Q; STP, RSTP, and MSTP; GVRP; QinQ; LLDP; Static MAC addresses, address filtering, and limit on the number of MAC addresses
IPv4 featuresStatic routing, BGP4, OSPF, IS-IS, and RIP; VRRP; ECMP; Policy-based routing; IP fragmentation and reassembly; Manual tunnel and GRE tunnel
IPv6 featuresStatic routing, BGP4+, OSPFv3, IS-ISv6, and RIPng; VRRPv3; ECMP; Policy-based routing; Path MTU discovery; IP fragmentation and reassembly; Manual tunnel and GRE tunnel; Pingv6, Traceroutev6, Telnetv6, FTPv6, TFTPv6, DNSv6, and ICMPv6
MulticastIGMP v1/v2/v3; IGMP Snooping v1/v2; IGMP proxy; PIM-DM, PIM-SM, PIM-SSM, and PIM-SM v6; MLDv1, MLDv2; Static multi cast route; Fast leave
MPLSMPLS L3VPN; MPLS LDP; SR MPLS (Segment Routing); SR-TE
ACLStandard, extended (Layer 2 to layer 4), and expert ACL; Global ACL; Ingress and egress ACL; IPv6 ACL
QoSIEEE 802.1p, ToS, and DSCP priority mapping; Priority marking and remarking; SP(PQ), DRR, SP(PQ)+DRR, WFQ, SP(PQ)+WFQ, WRR, SP(PQ)+WRR and other queue scheduling mechanisms; Congestion avoidance mechanisms such as RED and WRED; ACL; Egress/ingress port-based rate limit and CAR; #MPLS QoS
Data center features#SRv6; VXLAN bridge; VXLAN gateway; BGP-EVPN VXLAN; VXLAN mapping; VXLAN over IPv4; VXLAN over IPv6; M-LAG; RDMA
SDNOpenFlow 1.3
GüvenilirlikIndependent switch fabric modules and independent supervisor modules to implement thorough separation of the forwarding plane from the control plane; 1+1 redundancy for supervisor modules; N+M redundancy for switch fabric modules; N+M redundancy for power modules and fan modules; Midplane-free design to avoid single point of failures; Hot swapping of components; Hot patching for online patch upgrade; BPDU Guard/Loop Guard/Root guard; NSR; DLDP; FRR; GR for OSPF/IS-IS/BGP; BFD for VRRP/OSPF/BGP4/
SanallaştırmaVirtual switching unit (VSU)
Güvenlik#MACSec; Network foundation protection protocol (NFPP) and CPU Protection Policy (CPP); DDoS attack defense, ARP attack defense, and ICMP attack defense; DAI, port security, IP source guard, and port protection; uRPF; RADIUS and TACACS authentication, password security, hierarchical user management, and password protection; Source IP address restriction; Configuring the device not to send unknown multicast packets to the CPU; Suppression of unknown unicast, broadcast, and multicast packets; SSHv
YönetimConsole/AUX Modem/Telnet/SSHv2 CLI configuration; FTP, TFTP, Xmodem, and SFTP; SNMP v1/v2c/v3; Netconf; RMON; NTP clock; Fault alarm and auto-recovery; System operation log; Traffic analysis; Zero-Touch provisioning (ZTP); Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability; Telemetry; Buffer status monitoring and traffic microburst identification; Supported VXLAN OAM: VXLAN ping VXLAN tracert; Port mirroring, traffic mir
Temel Özellikler 3 satır
Dimensions (W × D × H)442 mm x 896 mm x 708 mm (17.40 in. X 35.28 in. X 27.87 in.), without the cable management bracket; 442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. X 27.87 in.), with the cable management bracket.
Çalışma Sıcaklığı0ºC to 40ºC (32ºF to 104ºF)
Çalışma Nemi10% RH to 90% RH (non-condensing)

Genel bakış

Ruijie RG-N18010-XH kullanım alanları ve özellikleri.

Adaptation to 400GE ZR/ZR+ optical modules, up to 288 x 400GE and 1152 x 100GE line-rate ports, and smooth evolution to 800GE

Data Center 400GE Modular Core Switch RG-N18010-XH

The RG-N18010-XH provides 10 module slots, including eight service slots, which can be used with 100GE and 400GE line cards. It supports 800GE line cards in the future, easily coping with future bandwidth expansion needs. With various port types, the RG-N18010-XH supports up to 288 x 400GE and 1152 x 100GE line-rate ports, and allows smooth evolution to 800GE, satisfying requirements in diversified scenarios of data center networks.

Innovative Architecture Design, Achieving Highly Efficient Data Transmission

Zero Midplane

Clos Architecture

Service line cards are directly connected to SFUs, without the use of the midplane. Data can directly reach the SFU, with a short distance. This significantly reduces the transmission loss and achieves efficient data transmission.

The Clos multi-level multi-platform switching architecture separates data forwarding from control, realizing high stability. This architecture delivers 1:1 non-convergence, link load balancing based on dynamic routes, and non-blocking data forwarding.

Communication at the Maximum Distance of 120 KM and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services

Hardware-level Redundancy, Ensuring Nonstop Services and Data Center Network Stability

SFUs in N+1 Redundancy Mode

SFUs use N+1 redundancy and work in load balancing mode, ensuring nonstop services.

Power Modules in M+N Redundancy Mode

Ten hot-swappable power modules are available. When a fault occurs, services are switched within seconds. Services are not interrupted when a power module is replaced. The switch provides different protection measures for links.

Fan Trays in 2+1 Redundancy Mode

Three hot-swappable fan trays are available. The speed of fan modules can be intelligently adjusted, ensuring highly efficient heat dissipation.

Supervisor Engines in 1+1 Redundancy Mode

The 1+1 hot standby design ensure continuous operation of the switch.

Innovative Technology Design and Highly Efficient Heat Dissipation

MACsec Data Encryption and Transmission, Effectively Protecting Service Data Security

MACsec provides hardware-level data encryption. With MACsec and 802.1X configured, the switch can strictly identify and verify transmitted data. With MACsec, the switch achieves interface-based secure line-rate transmission, effectively preventing data from being intercepted and obtained maliciously and ensuring service data security.

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Nerelerde kullanılır?

Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Dokümanlar

Veri sayfası ve kullanım kılavuzları.

Sık sorulanlar

RG-N18010-XH hakkında kısa yanıtlar.

RG-N18010-XH fiyatı ne kadar?
RG-N18010-XH için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-N18010-XH için fiyat ve teslim süresini iletelim.

Benzer ürünler

Yönetilebilir Switch

Tümü