Distribütör garantili ürünlerFaturalı satış · 81 ile sevkiyatAynı gün teklif

Ruijie RG-S6980-64QC 64 Port 400G QSFP-DD Veri Merkezi Switch

ModelRG-S6980-64QC

Ruijie RG-S6980-64QC bir yönetilebilir switch'tir. Öne çıkan özellikleri: high-density 400ge switch with 64 x 400ge qsfp-dd ports in the 4-ru space, hardware-level redundancy, ensuring service continuity, 400ge qsfp-dd ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication, lossless ethernet, ensuring zero packet loss during rdma e2e communication.

Port hızı
10G uplink
PoE
PoE yok
Fiyat ve stok bilgisi alınAynı gün dönüş

Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.

Distribütör garantili
81 ile sevkiyat
Teknik destek
  • High-density 400GE switch with 64 x 400GE QSFP-DD ports in the 4-RU space
  • Hardware-level redundancy, ensuring service continuity
  • 400GE QSFP-DD ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry-based network monitoring and automated O&M, making management simple and efficient

Teknik özellikler

Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.

Donanım Özellikleri 14 satır
Dimensions (W × D × H)442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in.)
Kabin Yüksekliği4 RU
Cihaz Ağırlığı32.8 kg (72.31 lbs., empty chassis); 42 kg (92.59 lbs., a chassis with four power modules and eight fan modules)
Anahtarlama Kapasitesi51.2 Tbps
Paket İletim Hızı10300 Mpps
Servis Portu64 x 100GE/200GE/400GE QSFP-DD ports
Yönetim Portu1 x RJ45 console port; 1 x RJ45 MGMT port
USB Portu1 x USB 2.0 port (Type A connector)
Güç Tüketimi4 x power module slots; 8 x fan module slots; Maximum power consumption: 2400 W; Typical power consumption: 1760 W; Static power consumption: 500 W
Güç GirişiRG-PA1200I-F (AC input); Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 13.8 A (100 V AC to 127 V AC); 8.5 A (200 V AC to 240 V AC); Power port type: C14; RG-PA1200I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 300 V DC; Rated current: 6.5 A
SıcaklıkOperating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 2000 m (6561.68 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.
NemOperating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing)
RakımOperating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.)
SoğutmaAir cooling, front-to-rear airflow (port-side intake)
Yazılım Özellikleri 11 satır
Layer 2 ProtocolsIEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol)), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB)
Layer 3 Protocols (IPv4)BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP
IPv6 Basic ProtocolsNeighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS
IPv6 FeaturesStatic routing, ECMP, PBR, OSPFv3, RIPng, BGP4+
Data Center FeaturesPFC, ECN, and other data center features; RDMA; VXLAN, BGP-EVPN; PFC deadlock prevention; RALB, AILB
VisualizationgRPC; sFLOW sampling
QoSMapping of IEEE 802.1p, DSCP, and ToS priorities; ACL-based traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR; Congestion avoidance mechanisms such as WRED and tail discarding
HA DesignGR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules
Security FeaturesNetwork foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management
Yönetim ModuSNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm
Other ProtocolsDHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog
Temel Özellikler 2 satır
Çalışma Sıcaklığı0ºC to 40ºC (32ºF to 104ºF)
Çalışma Nemi10% RH to 90% RH (non-condensing)

Genel bakış

Ruijie RG-S6980-64QC kullanım alanları ve özellikleri.

High-density 400GE Fixed Switch with 400GE ZR/ZR+ Optical Modules, Supporting Long-Distance Interconnection

Data Center 400GE Core Switch RG-S6980-64QC

High-speed and high-density core switch in a data center with 64 x 400GE QSFP-DD ports in the 4 RU space, delivering scalable, high-performance and high-bandwidth services and coping with interconnection on a large data center network

Ports

Dimensions

IPv4/IPv6 Host Routing Entries 1000K/640K

Buffer 113.66MB

Hardware-level Redundancy, Ensuring Service Continuity

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

Power modules in 2+2 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links

modules Fan modules in 7+1 redundancy mode, intelligent fan speed adjustment, and highly-efficient heat dissipation, building low-carbon data centers

Communication at the Maximum Distance of 120 km and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection reducing intermediate transmission devices and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services.

Lossless Ethernet with RDMA E2E Communication and Zero Packet Loss

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Nerelerde kullanılır?

Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.

Kurulum ve uyumluluk

Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.

Dokümanlar

Veri sayfası ve kullanım kılavuzları.

Sık sorulanlar

RG-S6980-64QC hakkında kısa yanıtlar.

RG-S6980-64QC fiyatı ne kadar?
RG-S6980-64QC için fiyat; adet, proje kapsamı ve güncel kura göre değiştiğinden teklif usulüyle verilir. Ürünü teklif listenize ekleyerek veya telefon/WhatsApp hattımızdan ulaşarak aynı iş günü içinde fiyat ve stok bilgisi alabilirsiniz.

Hızlı teklif

Formu doldurun, RG-S6980-64QC için fiyat ve teslim süresini iletelim.

Benzer ürünler

Yönetilebilir Switch

Tümü