Ruijie RG-S6980-64QC 64 Port 400G QSFP-DD Veri Merkezi Switch
RG-S6980-64QCRuijie RG-S6980-64QC bir yönetilebilir switch'tir. Öne çıkan özellikleri: high-density 400ge switch with 64 x 400ge qsfp-dd ports in the 4-ru space, hardware-level redundancy, ensuring service continuity, 400ge qsfp-dd ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication, lossless ethernet, ensuring zero packet loss during rdma e2e communication.
- Port hızı
- 10G uplink
- PoE
- PoE yok
Adet ve proje bilginize göre güncel fiyat, stok ve teslim süresini iletelim.
- High-density 400GE switch with 64 x 400GE QSFP-DD ports in the 4-RU space
- Hardware-level redundancy, ensuring service continuity
- 400GE QSFP-DD ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication
- Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
- Telemetry-based network monitoring and automated O&M, making management simple and efficient
Teknik özellikler
Üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
Donanım Özellikleri 14 satır
| Dimensions (W × D × H) | 442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in.) |
|---|---|
| Kabin Yüksekliği | 4 RU |
| Cihaz Ağırlığı | 32.8 kg (72.31 lbs., empty chassis); 42 kg (92.59 lbs., a chassis with four power modules and eight fan modules) |
| Anahtarlama Kapasitesi | 51.2 Tbps |
| Paket İletim Hızı | 10300 Mpps |
| Servis Portu | 64 x 100GE/200GE/400GE QSFP-DD ports |
| Yönetim Portu | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| USB Portu | 1 x USB 2.0 port (Type A connector) |
| Güç Tüketimi | 4 x power module slots; 8 x fan module slots; Maximum power consumption: 2400 W; Typical power consumption: 1760 W; Static power consumption: 500 W |
| Güç Girişi | RG-PA1200I-F (AC input); Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz; Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz; Rated input current: 13.8 A (100 V AC to 127 V AC); 8.5 A (200 V AC to 240 V AC); Power port type: C14; RG-PA1200I-F (HVDC input):; Rated input voltage: 240 V DC; Maximum input voltage: 180 V DC to 300 V DC; Rated current: 6.5 A |
| Sıcaklık | Operating temperature: 0°C to 40°C (32°F to 104°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At altitudes ranging from 2000 m (6561.68 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Nem | Operating humidity: 10% RH to 90% RH (non-condensing); Storage humidity: 5% RH to 95% RH (non-condensing) |
| Rakım | Operating altitude: ≤ 5,000 m (16,404.20 ft.); Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Soğutma | Air cooling, front-to-rear airflow (port-side intake) |
Yazılım Özellikleri 11 satır
| Layer 2 Protocols | IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol)), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
|---|---|
| Layer 3 Protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP |
| IPv6 Basic Protocols | Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
| IPv6 Features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
| Data Center Features | PFC, ECN, and other data center features; RDMA; VXLAN, BGP-EVPN; PFC deadlock prevention; RALB, AILB |
| Visualization | gRPC; sFLOW sampling |
| QoS | Mapping of IEEE 802.1p, DSCP, and ToS priorities; ACL-based traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR; Congestion avoidance mechanisms such as WRED and tail discarding |
| HA Design | GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
| Security Features | Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management |
| Yönetim Modu | SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm |
| Other Protocols | DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog |
Temel Özellikler 2 satır
| Çalışma Sıcaklığı | 0ºC to 40ºC (32ºF to 104ºF) |
|---|---|
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
Genel bakış
Ruijie RG-S6980-64QC kullanım alanları ve özellikleri.
High-density 400GE Fixed Switch with 400GE ZR/ZR+ Optical Modules, Supporting Long-Distance Interconnection
Data Center 400GE Core Switch RG-S6980-64QC
High-speed and high-density core switch in a data center with 64 x 400GE QSFP-DD ports in the 4 RU space, delivering scalable, high-performance and high-bandwidth services and coping with interconnection on a large data center network
Ports
Dimensions
IPv4/IPv6 Host Routing Entries 1000K/640K
Buffer 113.66MB
Hardware-level Redundancy, Ensuring Service Continuity
Hot-Swappable Redundant Power Modules
Hot-Swappable Redundant Fan Modules
Power modules in 2+2 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links
modules Fan modules in 7+1 redundancy mode, intelligent fan speed adjustment, and highly-efficient heat dissipation, building low-carbon data centers
Communication at the Maximum Distance of 120 km and Easy DCI
400GE ZR/ZR+ optical modules are used for interconnection reducing intermediate transmission devices and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services.
Lossless Ethernet with RDMA E2E Communication and Zero Packet Loss
With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem. PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with telemetry provides clear data status and hierarchy. The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-S6980-64QC hakkında kısa yanıtlar.
RG-S6980-64QC fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-S6980-64QC için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6930-2C 2 Slot Modüler Veri Merkezi Switch
Ruijie RG-S6980-128DC 128 Port 200G QSFP56 Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6910-3C 3 Slot Modüler Veri Merkezi Switch





