- Port hızı
- Gigabit
- PoE
- PoE yok
- Port sayısı
- 16 port
- Various port combinations, rate increase, surge protection greater than 8 kV, 16 x 10/100/1000BASE-T ports , and 2 x 1GE SFP ports for uplink
- Small size, flexible and fast installation, efficient heat dissipation, and low noise
- Reliability enhancement, metal enclosure, metal Ethernet ports, independent optical transceiver design, and more stable data forwarding
- Easy and effective network-wide management, ensuring high security and reliability for networks
Genel bakış
Ruijie RG-SF2920-16GT2SFP özellikleri ve kullanım alanları.
Various port combinations, rate increase, installation in a concealed telecommunication box, recommended for indoor use, aesthetically pleasing design, and security
All-Optical Ethernet Switch RG-SF2920-16GT2SFP
The Ethernet architecture and novel Fiber-to-the-Room (FTTR) deployment delivers 1G fiber-to-the-room access. This switch provides 16 x 10/100/1000BASE-T ports, 2 x 1GE SFP uplink ports, rich interfaces, supporting full service expansion.
Ports
Dimensions
Small Size, Space Saving, Aesthetically Pleasing Design, and No Security Concern
Flexible Installation
Heat Dissipation Design
Quietness
This compact switch comes with various mounting brackets to suit different environments. It can be flexible installed under a workbench, on a wall, in a customized cabinet or in a concealed ELV box.
The new shark fin design and die-casting enclosure increase the dissipation area by 37%. This switch can be fit into an ELV box safely and neatly.
Fanless design, noise < 20 dB, barely perceptible to the human ear.
Enhanced Reliability, Independent Optical Transceiver Design, and More Stable Data Forwarding
In the traditional POL optical solution, ONUs use an on-board optical transceiver design. However, there is a trade-off between the signal quality and welding reliability, resulting in a high failure rate. The Simplified Optical Ethernet solution adopts point-to-point transmission and provides a more reliable independent optical transceiver design. The high-quality signal transmission is free from external interference and data forwarding is more stable.
Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations
RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Sabit Servis Portları | 16 x 10/100/1000BASE-T ports; 2 x 1GE SFP ports |
|---|---|
| Sabit Yönetim Portu | 1 x RJ45 console port |
| Sistem Paket İletim Hızı | 26.8 Mpps |
|---|---|
| Sistem Anahtarlama Kapasitesi | 36 Gbps |
| İşlemci (CPU) | Single-core CPU, with the clock speed of 1 GHz |
| Flash Bellek | 256 MB |
| Bellek | 512 MB DDR3 |
| Switch Tampon Belleği | 1.5 MB |
| MAC Adres Sayısı | Number of global MAC addresses: 16,000; Number of static MAC addresses: 1,000 |
| ARP Tablosu Boyutu | 1,000 |
| Number of IPv4 unicast routes | 500 |
| Number of IPv6 unicast routes | 500 |
| Number of ACEs | Ingress: 1,500; Egress: 500 |
| Cihaz Boyutları (G x D x Y) | 210 mm x 235 mm x 55 mm (8.27 in. x 9.25 in. x 2.17 in.) |
|---|---|
| Kutu Boyutları (G x D x Y) | 529 mm x 336 mm x 334 mm (20.83 in. x 13.23 in. x 13.15 in.) |
| Kabin Yüksekliği | 1 RU |
| Cihaz Ağırlığı | 1.98 kg (4.37 lbs) |
| Kutulu Ağırlık | 2.75 kg (6.06 lbs) |
| Güç Kaynağı | 1 x fixed power module |
|---|---|
| Güç Girişi | AC input; Rated input voltage: 200 V AC to 240 V AC, 50/60 Hz; Maximum input voltage: 180 V AC to 264 V AC, 47 Hz to 63 Hz; Maximum input current: 0.6 A |
| Maks. Çıkış Gücü | Fixed power supply: 25 W |
| Maks. Güç Tüketimi | 25 W |
| Energy saving | Energy Efficient Ethernet (EEE) |
| Ortam ve Güvenilirlik | RG-SF2920 Series |
|---|---|
| Sıcaklık | Operating temperature:; ELV box: 0 to 40℃ (–32°F to +104°F); Workbench/Wall: 0 to 40℃ (–32°F to +104°F); Rack: 0 to 45℃ (–32°F to +113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F); Note: At an altitude between 1,800 m (5,905.51 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F). |
| Nem | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| Rakım | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
| MTBF | 300,000 hours (about 34 years) |
| Fan | Fanless |
| Isı Dağılımı | Fanless design, natural heat dissipation |
| Cable hot swapping | Supported by all ports |
| Sıcaklık İzleme | Temperature monitoring, over-temperature alarming |
| ESD Koruması | Air discharge: 15 kV; Contact discharge: 8 kV |
| Aşırı Gerilim Koruması | Service port: 8 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Güvenlik Standardı | IEC 62368-1 |
|---|---|
| EMC Standardı | EN 300386, EN 55032 Class A, EN 55035,; EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,; EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
| Ethernet Anahtarlama | Jumbo frame length: 9,216 bytes; IEEE 802.3az EEE; Maximum number of VLANs that can be created: 4,094; Voice VLAN; Private VLAN; MAC VLAN; MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment; GVRP; Basic QinQ and flexible QinQ; STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s); ERPS (G.8032) with switching time ≤ 50 ms; LLDP/LLDP-MED |
|---|---|
| IP Servisleri | DHCP server, DHCP client, and DHCP snooping; DNS; DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping; Neighbor Discovery (ND) |
| IP Yönlendirme | Static routing; Static blackhole routing; RIP v1/v2 and RIPng; OSPFv2 and OSPFv3; GR |
| Multicast | IGMPv1/v2/v3 snooping; IGMP fast leave |
| ACL ve QoS | Standard IP ACLs (IP-based hardware ACLs); Extended IP ACLs; Extended MAC ACLs; Expert-level ACLs; ACL80 and IPv6 ACLs; ACLs on Layer 2 and Layer 3 interfaces; Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range); ACL redirection; Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences; Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, |
| Güvenlik | RADIUS and TACACS+; RADIUS authentication and authorization; IEEE 802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication; Web authentication; Hypertext Transfer Protocol Secure (HTTPS); SSHv1.5 and SSHv2.0; Global IP-MAC binding; ICMP (discarding ICMP packets of which the rate exceeds the threshold on an interface); Port security; BPDU guard; Filtering of invalid MAC addresses; Broadcast storm suppression; Hierarchical mana |
| Güvenilirlik | REUP; Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control; Load balancing; LACP dynamic aggregation; The LACP priority, negotiation mode, and maximum number of ports that can be aggregated can be configured.; Cross-VSU aggregate interface; DLDP; IPv4 VRRP v2/v3, IPv6 VRRPv3; GR for OSPF |
| Ağ Yönetimi ve Bakım | SPAN, RSPAN and ERSPAN; Flow- and VLAN-based SPAN; 1:1 mirroring, N:1 mirroring, and 1:N mirroring; Cross-device traffic mirroring; sFlow (network detection technology based on packet sampling, which is mainly used for traffic statistics and analysis in heavy-traffic scenarios); NTP and SNTP; FTP and TFTP; SNMP v1/v2c/v3; RMON (1, 2, 3, 9); CLI (Telnet/console), Syslog/debugging, and web; Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, a |
| PoE | RG-SF2920-16GT2SFP-P, RG-SF2920-8GT2MG2XS-P, and RG-SF2920-16GT2MG2XS-P:; RJ45 ports in compliance with IEEE 802.3af (15.4 W) and IEEE 802.3at (30 W); Automatic and energy-efficient power supply management modes; Warm start to implement uninterrupted power supply; Port priority |
| Sistem Paket İletim Hızı | 26.8 Mpps |
|---|---|
| Sistem Anahtarlama Kapasitesi | 36 Gbps |
| Depolama Sıcaklığı | –40°C to +70°C (–40°F to +158°F) |
| Warranty period | 3 years |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-SF2920-16GT2SFP hakkında kısa yanıtlar.
RG-SF2920-16GT2SFP kaç portlu?
RG-SF2920-16GT2SFP fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-SF2920-16GT2SFP için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-SF2920 serisi
Ruijie RG-SF2920-16GT2MG2XS-P 16 Port Gigabit PoE+ 2×2.5G 2×10G SFP+ Yönetilebilir Switch
Ruijie RG-SF2920-16GT2MG2XS 16 Port Gigabit 2×2.5G 2×10G SFP+ Yönetilebilir Switch
Ruijie RG-SF2920-16GT2SFP-P 16 Port Gigabit PoE+ 2×SFP Yönetilebilir Switch
Ruijie RG-SF2920-8GT2MG2XS 8 Port Gigabit 2×2.5G 2×10G SFP+ Yönetilebilir Switch