Ruijie RG-SG7008L 4 Port 10G SFP+ Yönetilebilir Switch
RG-SG7008LRuijie RG-SG7008L, 4 portlu gigabit bir yönetilebilir switch'tir. 8 adet SFP portu ile fiber uplink bağlantısı kurulabilir. VLAN, QoS ve port izleme gibi yönetim özellikleri sunar.
- Port hızı
- Gigabit
- PoE
- PoE yok
- Port sayısı
- 4 port
- ODON Solution: Redefining Small and Medium-Sized Campus Networks
- ODON Master Device with Multi-Service Integration
- Modular Design for Flexible Combination of Line Cards, Meeting Diverse Network Needs
- Clos Architecture for Shorter, Interference-Free Data Transmission
- Streamlined O&M with Embedded RG-INC-EMB and WIS Cloud
Genel bakış
Ruijie RG-SG7008L özellikleri ve kullanım alanları.
Interworking with remote units as a core/aggregation switch in Small and Medium-Sized networks, enabling flexible networking
RG-SG7008L, Fixed 10GE ODON Master Device
The ODON master device serves as a core or aggregation device in Small and Medium-Sized networks, providing 1GE and 10GE optical ports. It integrates switching, wireless, routing, and basic security features, with indoor remote units, serving the whole campus through one network.
ODON Solution: Redefining Small and Medium-Sized Campus Networks
Designed for Small and Medium-Sized campus scenarios, One Device for One Network (ODON) Solution adopts a combination of an ODON Master Device and remote units to simplify the network architecture and reduce deployment costs, meeting the demands of rapid secure access and efficient data transmission on campus networks.
ODON Master Device with Multi-Service Integration
Integrating the functions of switches, wireless access controllers (ACs), routers, and software-defined networking (SDN) platforms for multi-purpose use, the RG-SG7008L works with in-room switches, access switches as a core or aggregation switch in Small and Medium-Sized networks, enabling flexible networking.
Modular Design for Flexible Combination of Line Cards, Meeting Diverse Network Needs
The device supports a flexible combination of various line cards. You can purchase different types of line cards as needed. Each line card has independent calculating modules and is separated from others, meeting various service deployment requirements.
Clos Architecture for Shorter, Interference-Free Data Transmission
The advanced Clos architecture adopts an orthogonal design for the switch fabric module and line cards. Data is transmitted to the switch fabric module directly without traversing the backplane, shortening the signal transmission path. Signal transmission and anti-interference capabilities are improved, ensuring interference-free data transmission.
VSU, Delivering Flexible Networking Capabilities and High Performance
The VSU technology virtualizes multiple physical devices into ore logical unit. The devices are operated and managed in a unified manner, significantly reducing network nodes and simplifying O&M. Link failover in milliseconds ensures uninterrupted transmission of critical services.
Streamlined O&M with Embedded RG-INC-EMB
The ODON Master Device integrated with either a cloud-based or local O&M platform offers the plug and play capability. This simplifies maintenance and enables rapid deployment, allowing network-wide management with a single switch.
Nerelerde kullanılır?
Kurumsal ağlarda VLAN ile kamera, misafir ve ofis trafiğini ayırmak, uplink ve omurga bağlantılarını yönetmek için kullanılır.
Kurulum ve uyumluluk
Ruijie Cloud üzerinden uzaktan yapılandırma ve izleme yapılabilir.
Teknik özellikler
Değerler üretici veri sayfasından derlenmiştir; proje öncesi güncel datasheet ile teyit edilmesi önerilir.
| Fixed ports | 4 x 1GE/10GE SFP+ ports |
|---|---|
| Yönetim Portları | 1 x console port, 1 x USB port, compliant with the USB 2.0 standard |
| Modül Yuvaları | 6 x common service card slots (slots 1--6); 2 x multi-service module slots (slots 7 and 8); 2 x power module slots (slots PWR1 and PWR2); 1 x hard disk slot; Built-in switch fabric unit (SFU) and fan modules |
| Multi-service card slots | M7000L-6XS (6 x 10GE optical interface ports); M7008L-RCM (routing card); M7008L-WSM (wireless card) |
| Common service card slots | M7000L-8GT (8 x GE Ethernet interface card); M7000L-8SFP (8 x GE optical interface card) |
| Hard disk slot | M7000L-HDD-1T (1 TB hard disk can be expanded.) |
| Anahtarlama Kapasitesi | 416 Gbps |
|---|---|
| Paket İletim Hızı | 310 Mpps |
| Boyutlar (G x D x Y) | Chassis without cable management arm (2 U): 442 mm x 320 mm x 88 mm (17.40 in. x 12.60 in. x 3.46 in.); Chassis with cable management arm (3 U): 442 mm x 406 mm x 131.5 mm (17.40 in. x 15.98 in. x 5.18 in.) |
|---|---|
| Ağırlık | Net weight: about 5.95 kg (13.12 lbs.) |
| Güç Modülü | RG-PA180I-F:; Input: 90 V--290 V AC; Output power: 180 W (12 V/180 W) |
|---|---|
| Güç Yedekliliği | Support 1+1 redundancy and current sharing. |
| Fixed fan modules | 3 x built-in fan modules; Fan speed adjustment and fan failure alarming are supported. |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) |
|---|---|
| Depolama Sıcaklığı | --40°C to +70°C (--40°F to +158°F) |
| Çalışma Nemi | 10% RH to 90% RH (non-condensing) |
| Depolama Nemi | 5% RH to 95% RH |
| Rakım | Long-term operating altitude: 0 m to 1800 m (0°C to 45°C, 32°F to 113°F); Note: At an altitude from 1800 m (5906 ft) to 5000 m (16404 ft), the maximum temperature decreases by 1°C (1.8°F) each time the altitude increases by 220 m (722 ft).; Operating altitude: up to 5000 m (16404 ft); Storage altitude: up to 5000 m (16404 ft) |
| Switching module - VLAN | 4000 IEEE 802.1Q VLANs; Port-based VLAN; Private VLAN; Voice VLAN; GVRP |
|---|---|
| Switching module - QinQ | Basic QinQ; Flexible QinQ |
| Switching module - Link aggregation | LACP (IEEE 802.3ad) |
| Switching module - Spanning tree protocols | STP, RSTP, and MSTP |
| Switching module - VXLAN | The hardware supports Virtual Extensible LAN (VXLAN). Through software upgrade in the future, a logical Layer 2 network can be built on the basis of the Layer 3 network. |
| Switching module - DHCP | DHCP server; DHCP client; DHCP snooping; DHCP relay; IPv6 DHCP server; IPv6 DHCP snooping; IPv6 DHCP client; IPv6 DHCP relay |
| Switching module - IP routing | RIP and RIPng; BGP4 and BGP4+; OSPFv2, OSPFv3, IS-ISv4, and IS-ISv6; Packet-based and flow-based load balancing |
| Switching module - Multicast | IGMPv1/IGMPv2/IGMPv3 and IGMP proxy; PIM-DM, PIM-SM, and PIM-SSM; MLD Snooping and MLD; PIM for IPv6 |
| Switching module - ACL | Flexible and diversified hardware ACLs; Standard IP ACLs (IP-based hardware ACLs); Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers); MAC-based extended ACLs; Time-based ACLs; Expert-level ACLs; IPv6 ACL |
| Switching module - Basic security features | 3-tuple binding (IP address, MAC address, and port); Filtering of unauthorized MAC addresses; 802.1x authentication based on the port number and MAC address; Portal authentication and Portal 2.0 authentication; ARP check, ARP packet rate limiting, gateway-targeted ARP spoofing prevention; Port protection; Broadcast storm suppression; Hierarchical management and password protection of administrators; RADIUS and TACAS+; AAA for device login management; SSHv2 to provide a secure, encrypted connecti |
| Switching module - Management features | SNMP, CLI (Telnet/Console), RMON, SSH, syslog, NTP/SNTP, SNMP over IPv6, IPv6 MIB support for SNMP, SSH over IPv6, Telnetv6, FTPv6/TFTPv6, DNSv6, NTP for IPv6, and Traceroute for IPv6; CLI configurations including the console port, auxiliary port, Telnet, or SSH; File transfer protocols such as FTP, TFTP, and XMODEM; sFlow, which utilizes the random sampling technology to sample flow information on the traffic of a switch; WIS-based management |
| Switching module - High reliability | VSU (virtualizing multiple devices into one device); BFD; ERPS (G.8032); REUP; RLDP; 1+1 power redundancy; Hot swapping of power modules |
| Routing module - IPv4 features | LLDP, 802.1Q, 802.1p, 802.3ad, and other Ethernet features; Static routing, RIPv1/RIPv2, OSPFv2, BGP, IS-IS, PBR, and routing policies; VRRP, FTP, and TFTP; ECMP and WCMP; Static and dynamic NAT, static and dynamic NAPT, and VPN NAT; DNS resolution and smart DNS; NTP server and NTP client |
| Routing module - IPv6 features | IPv6 addressing, Neighbor Discovery (ND), ICMPv6, Stateless Auto Configuration, and Path MTU Discovery; Static routing, RIPng, OSPFv3, BGP4+, IS-ISv6, ECMP, and PBR; VRRPv3, BFDv6, and 6VPE; IPv6 ACL, NAT64, NAT-PT, DHCPv6, DNSv6, FTPv6, and TFTPv6; Manual tunnel, automatic tunnel, ISATAP, and GRE tunnel |
| Routing module - MPLS | MPLS forwarding, MPLS VPN/VPLS; MPLS VPN inter-AS option A/B/C |
| Routing module - SSL VPN | Enabled by default; supporting access on the web page and iOS, macOS, Windows, and Android clients |
| Routing module - Egress features | User management, ACE based on user groups, and rate limiting for individual users; Egress routing, ISP address library, Reverse Path Limited (RPL), domain name-based routing, and multi-link load balance (MLLB); DNS proxy, reverse DNS proxy, and DNS redirect; Flow table-based attack prevention, single-user session limit, flow attack log, and flow table memory optimization; Configuration backup and one-click recovery; Flow log and URL log |
| Routing module - Security zone | Security zone division based on the IP address; Security zone division based on the logical interface; Attack defense domain (global protection policies, protocol policies, and domain policies); Security audit (attack defense domain log audit, security zone log audit, and management log audit) |
| Routing module - URL filtering | Self-defined URL and URL logs; Automatic remote upgrade of URL library through HTTP; Local storage of logs and storage on external log servers (including NAT logs, flow logs, and URL logs) |
| Routing module - Attack prevention | ARP attack prevention; LAN attack prevention and WAN attack prevention; Secure address binding; Port scan attack prevention; Segmentation packet attack prevention; ICMP flood attack prevention; Smurf attack prevention; Teardrop attack prevention; ICMP redirect attack prevention; ICMP unreachable attack prevention |
| Routing module - Application Identification | Self-developed application identification function that can identify various application types, customizable application identification protocol; P2P applications; Streaming media software; Chat software; Game software; Internal enterprise applications |
| Routing module - Content audit | Email content audit; IM audit; BBS forum content audit; Search engine audit |
| Wireless module (M7008L-WSM) - Default number of managed APs | 0; Note: The default number of APs that can be managed by the M7008L-WSM is subject to the AP model. For details, see the Ordering Information. |
| Wireless module (M7008L-WSM) - Maximum number of managed APs | 512; Note: The maximum number of APs that can be managed by the M7008L-WSM is subject to the AP model. For details, see the Ordering Information. |
| Wireless module (M7008L-WSM) - Intra-AC roaming handoff time | < 50 ms |
| Wireless module (M7008L-WSM) - IEEE 802.11 protocols | 802.11, 802.11b, 802.11a, 802.11g, 802.11d, 802.11h, 802.11w, 802.11k, 802.11v, 802.11r, 802.11i, 802.11e, 802.11n, 802.11ac, and 802.11ax |
| Wireless module (M7008L-WSM) - CAPWAP protocol | Layer 2 and Layer 3 topology supported between an AP and an AC; An AP can automatically discover the accessible AC.; An AP can be automatically upgraded through the AC.; An AP can automatically download the configuration file from the AC.; CAPWAP through NAT |
| Wireless module (M7008L-WSM) - Roaming | Intra-AC Layer 2 or Layer 3 roaming; Inter-AC Layer 2 or Layer 3 roaming; Intra-AC Layer 2 or Layer 3 roaming in local forwarding mode; Inter-AC Layer 2 or Layer 3 roaming in local forwarding mode |
| Wireless module (M7008L-WSM) - User isolation | AC-based user isolation; AP-based user isolation; WLAN-based user isolation |
| Wireless module (M7008L-WSM) - STA management | Access control based on the number of STAs associated with the AP; Access control based on the number of STAs associated with the SSID; Balanced access control based on the number of STAs associated with the AP; Balanced access control based on the AP traffic; Band steering; RSSI threshold for STA access |
| Wireless module (M7008L-WSM) - Wireless QoS | AP-based bandwidth limiting; WLAN-based bandwidth limiting; Static and intelligent rate limiting based on STA quantity; Fair scheduling |
| Wireless module (M7008L-WSM) - RF management | Country or region code setting; Manual setting of the transmit power; Automatic setting of the transmit power; Manual setting of the operating channel; Automatic setting of the operating channel; Automatic adjustment of the data rate; Coverage Hole Detection; AP load balancing based on traffic and STA quantity; Band selection; Radio frequency interference (RFI) detection and mitigation |
| Wireless module (M7008L-WSM) - AP virtualization | Destekleniyor |
| EMB module - Device status query | Query device details, CPU/memory usage, interface status, temperature, power supply, fan, traffic, and bandwidth utilization |
| EMB module - Network configuration | VLAN management, trunk management, port setting, aggregate port, port mirroring, port rate limiting, static routing, DHCP, DHCP snooping, STP loop guard, RLDP, and remote power supply management |
| EMB module - Zero-configuration features | CPE WAN Management Protocol (CWMP) |
| EMB module - Network management configurations | Syslog, Telnet, and SNMP |
| EMB module - Diagnosis tools | Network detection and one-click information collection |
| EMB module - Operations on devices | Upgrade, restart, configuration management, system time, log server, DNS server, system character set, and web console |
| EMB module - Quick configuration | Quick configuration |
| EMB module - Operation log | Log query, log type, and log management |
| EMB module - Device upgrade | Device upgrade |
| EMB module - Administrator account | Web administrator configuration |
| EMB module - Data backup and recovery | Data backup download, data import and recovery |
| İşlemci (CPU) | Quad-core processor |
|---|---|
| BootROM | 16 MB, and dual boot for active and standby chips |
| Flash Bellek | 4GB |
| SDRAM | 4GB |
| External Port | 1 x console port |
| Buton | 1 x FUNC button |
| Sıcak Takas | Destekleniyor |
| EMC Standardı | EN 55032: 2015+A1: 2020; EN 61000-3-3: 2013+A1: 2019+A2: 2021; EN IEC 61000-3-2: 2019+A1: 2021; EN 55035: 2017+A11: 2020; EN 300386 V2.2.1; BS EN 55035: 2017+A11: 2020; BS EN IEC 610000-3-2: 2019+A1: 2021; BS EN 61000-3-3: 2013+A1: 2019+A2: 2021; BS EN 55032: 2015+A1: 2020 |
| Güvenlik Standardı | BS EN 62368-1: 2014+A11: 2017 |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m (16404.20 ft.) |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.30 kg (0.66 lbs) |
| Boyutlar (G x D x Y) | Without captive screws: 86 mm x 208 mm x 38 mm (3.39 in. x 8.19 in. x 1.50 in.); With captive screws: 86 mm x 220 mm x 38 mm (3.39 in. x 8.66 in. x 1.50 in.) |
| İşlemci (CPU) | Quad-core processor |
|---|---|
| BootROM | 16 MB, and dual boot for active and standby chips |
| Flash Bellek | 4GB |
| SDRAM | 4GB |
| External Port | 1 x console port |
| Buton | 1 x FUNC button |
| Sıcak Takas | Destekleniyor |
| EMC Standardı | EN 55032: 2015+A1: 2020; EN 61000-3-3: 2013+A1: 2019+A2: 2021; EN IEC 61000-3-2: 2019+A1: 2021; EN 55035: 2017+A11: 2020; EN 300386 V2.2.1; BS EN 55035: 2017+A11: 2020; BS EN IEC 610000-3-2: 2019+A1: 2021; BS EN 61000-3-3: 2013+A1: 2019+A2: 2021; BS EN 55032: 2015+A1: 2020 |
| Güvenlik Standardı | BS EN 62368-1: 2014+A11: 2017 |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m (16404.20 ft.) |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.30 kg (0.66 lbs) |
| Boyutlar (G x D x Y) | Without captive screws: 86 mm x 208 mm x 38 mm (3.39 in. x 8.19 in. x 1.50 in.); With captive screws: 86 mm x 220 mm x 38 mm (3.39 in. x 8.66 in. x 1.50 in.) |
| Port Type | 6 x SFP+ ports, supporting the 10G SFP+ module and 1G SFP module (there are slot limitations on the 1G SFP module) |
|---|---|
| Optical Module | SFP+ port; SFP modules and SFP BIDI modules; SFP+ modules, SFP+ cables, and SFP+ BIDI modules |
| LED | RDY, Link/ACT LED |
| EMC Standard | GB/T 9254.1 |
| Sıcak Takas | Destekleniyor |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.30 kg (0.66 lbs) |
| Boyutlar (G x D x Y) | Without captive screws: 86 mm x 209 mm x 38 mm (3.39 in. x 8.23 in. x 1.50 in.); With captive screws: 86 mm x 220 mm x 38 mm (3.39 in. x 8.66 in. x 1.50 in.) |
| Port | 8 x 10/100/1000BASE-T RJ45 ports |
|---|---|
| Transmission Medium | 10/100/1000BASE-T Category 5 UTP |
| LED | RDY function module status LED or 10/100/1000Base-T Ethernet port LED |
| Sıcak Takas | Destekleniyor |
| EMC Standardı | EN 55032: 2015+A1: 2020; EN 61000-3-3: 2013+A1: 2019+A2: 2021; EN IEC 61000-3-2: 2019+A1: 2021; EN 55035: 2017+A11: 2020; EN 300386 V2.2.1; BS EN 55035: 2017+A11: 2020; BS EN IEC 610000-3-2: 2019+A1: 2021; BS EN 61000-3-3: 2013+A1: 2019+A2: 2021; BS EN 55032: 2015+A1: 2020 |
| Güvenlik Standardı | BS EN 62368-1: 2014+A11: 2017 |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.20 kg (0.44 lbs) |
| Boyutlar (G x D x Y) | Without captive screws: 198 mm x 86 mm x 38 mm (7.80 in. x 3.39 in. x 1.50 in.); With captive screws: 210 mm x 86 mm x 38 mm (8.27 in. x 3.39 in. x 1.50 in.) |
| Port | 8 x SFP ports that support the 1G SFP module |
|---|---|
| Optical Module | SFP modules and SFP BIDI modules |
| LED | RDY function module status LED and SFP port LED |
| Sıcak Takas | Destekleniyor |
| EMC Standardı | EN 55032: 2015+A1: 2020; EN 61000-3-3: 2013+A1: 2019+A2: 2021; EN IEC 61000-3-2: 2019+A1: 2021; EN 55035: 2017+A11: 2020; EN 300386 V2.2.1; BS EN 55035: 2017+A11: 2020; BS EN IEC 610000-3-2: 2019+A1: 2021; BS EN 61000-3-3: 2013+A1: 2019+A2: 2021; BS EN 55032: 2015+A1: 2020 |
| Güvenlik Standardı | BS EN 62368-1: 2014+A11: 2017 |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.25 kg (0.55 lbs) |
| Boyutlar (G x D x Y) | Without captive screws: 199 mm x 86 mm x 38 mm (7.83 in. x 3.39 in. x 1.50 in.); With captive screws: 210 mm 86 mm x 38 mm (8.27 in. x 3.39 in. x 1.50 in.) |
| Rated Voltage Range | 110 V/220 V AC, 50 Hz to 60 Hz |
|---|---|
| Maximum Voltage Range | 90 V AC to 290 V AC, 45 Hz to 65 Hz |
| Maks. Çıkış Gücü | 180 W |
| HVDC Parameters | 192 V DC to 290 V DC, 2A Max., 180 W |
| Ağırlık | 0.45 kg (0.99 lbs) |
| Power Cord | 10 A |
| Hard Drive Type | Hard Disk Drive (HDD) |
|---|---|
| Kapasite | 1 TB |
| LED | DISK status LED |
| Sıcak Takas | Desteklenmiyor |
| EMC Standardı | EN 55032: 2015+A1: 2020; EN 61000-3-3: 2013+A1: 2019+A2: 2021; EN IEC 61000-3-2: 2019+A1: 2021; EN 55035: 2017+A11: 2020; EN 300386 V2.2.1; BS EN 55035: 2017+A11: 2020; BS EN IEC 610000-3-2: 2019+A1: 2021; BS EN 61000-3-3: 2013+A1: 2019+A2: 2021; BS EN 55032: 2015+A1: 2020 |
| Güvenlik Standardı | BS EN 62368-1: 2014+A11: 2017 |
| Rakım | Maximum operating altitude: 5000 m (16404.20 ft.); Maximum storage altitude: 5000 m |
| Çalışma Sıcaklığı | 0°C to 45°C (32°F to 113°F) (0 m to 1800 m); For the altitude in the range of 1800 m (5905.51 ft.) to 5000 m (16404.20 ft.), every time the altitude increases by 200 m (656.17 ft.), the operating temperature is decreased by 1°C (1.8°F). |
| Çalışma Nemi | 10% to 90% RH (non-condensing) |
| Depolama Sıcaklığı | -40°C to +70°C (-40°F to +158°F) |
| Depolama Nemi | 5% to 95% RH (non-condensing) |
| Ağırlık | 0.30 kg (0.66 lbs) |
| Boyutlar (G x D x Y) | 159 mm x 100.2 mm x 20.5 mm (6.30 in. x 3.94 in. x 0.81 in.) |
Dokümanlar
Veri sayfası ve kullanım kılavuzları.
Sık sorulanlar
RG-SG7008L hakkında kısa yanıtlar.
RG-SG7008L kaç portlu?
RG-SG7008L fiyatı ne kadar?
Hızlı teklif
Formu doldurun, RG-SG7008L için fiyat ve teslim süresini iletelim.
Yönetilebilir Switch kategorisinden
Ruijie RG-S6990-128QC2XS 128 Port 400G QSFP-DD 2×10G SFP+ Veri Merkezi Switch
Ruijie RG-S6580-24DC8QC 24 Port 200G QSFP56 8×400G QSFP-DD Veri Merkezi Switch
Ruijie RG-S6580-48CQ8QC 48 Port 100G QSFP28 8×400G QSFP-DD Veri Merkezi Switch